46
E
: Packet Length: packet length available for the test, from 64 to 1518 bytes
F
: Transfer Rate (Mbps): The transmission throughput in Mbps. Please input value that fit the real network
environment; otherwise, packet loss would happen.
G
: Test Time (second): Test duration of a single test.
H
: Apply: Click to take effect the configuration
Command
I
: The default test speed is 1000Mbps Full
J
: Test Time (second): The duration in seconds that is going on currently. The parameter of duration can be
configured at the time rotary switch on the panel of NuBAR-1000.
K
: Button to control the procedure
Stop (button): Stop the test. If Test Time (second) is configured. Wait the system to stop the test
automatically, otherwise, force to stop the test immediately get the failed test result.
Start (button): Start the test.
L
: Transmit Counter from Lord NuBAR-1000 in symmetric loop test.
M
: MAC: MAC address of Lord NuBAR-1000
N
: Tx Rate: Transfer rate of ongoing test stream.
O
: Tx Maximum Rate: Maximum transfer rate of ongoing test stream.
P
: Tx Packet: Transmitted packet counts
Q
: Tx Byte: Transmitted data bytes.
R
: Received Counter at Servant NuBAR-1000 in symmetric loop test.
S
: MAC: MAC address of Servant NuBAR-1000
T
: Rx Rate: Receive rate from ongoing test stream generated from Lord NuBAR-1000.
U
: Rx Packet: Received packet counts
V
: Rx Byte: Received data bytes.
W
: CRC Error: CRC error packet counts found from received packet
X
: Packet Loss: Packet loss counts found in received packets.
A1
: Transmit Counter from Servant NuBAR-1000 to Lord NuBAR-1000 in symmetric loop test.
Tx Rate: Transfer rate of ongoing test stream.
Tx Packet: Transmitted packet counts
Tx Byte: Transmitted data bytes.
Y
: Received Counter at Lord NuBAR-1000 that is transmitted from Servant NuBAR-1000 in symmetric loop
test.