background image

ADPRO FastTrace - Quick Setup Guide

Asia / Pacific

Vision Fire & Security
Private Bag 215
495 Blackburn Road
Mount Waverley Vic 3149
Australia
Ph

+61 3 9211 7300

Fax +61 3 9211 7202
Toll Free 1800 700 203

The Americas

Vision Fire & Security
700 Longwater Drive
Norwell Massachusetts 02061 USA
Ph

+1 781 740 2223

Fax

+1 781 740 4433

Toll Free 800 229 4434

Europe & the Middle East

Vision Fire & Security
Vision House
Focus 31, Mark Road
Hemel Hempstead Herts HP2 7BW UK
Ph

+44 (0) 1442 242 330

Fax

+44 (0) 1442 249 327

Web Site

http://www.adpro.com.au

The manufacturer reserves the right to change designs or specifications without obligation and without further
notice. ADPRO, FastTrace, FastVu, Fast Scan, Axiom, PRO, Amux and Video Central are brands and trademarks
used under licence by the distributor.

Printed: June 2003  P/N 201335.06

Quality
Endorsed
Company
ISO 9001:2000
Lic. QEC 2868

Troubleshooting Tips:

 

Ensure that matching details entered at the FastTrace PC Viewer 

AND

 at the site equipment are 

IDENTICAL

 

If using a serial port connection, check the port configuration in the PC is set for the correct speed and data
configuration to match the modem type used

 

If using a network connection, ensure the TCP/IP address and subnet mask are correct

IMPORTANT NOTES

Setting the Date and Time:

The ADPRO FastTrace uses a stable internal clock that is based on UCT (Universal Coordinated Time). Date and time
settings of the unit operate in a way that is similar to a PC and a  'Time Zone' value is provided in the 

Date / Time

Settings

 option of the 

Site Details

 menu.

To ensure correct operation, the Time Zone value should be configured prior to any date or time changes being made.

Windows NT on the PC

When Windows NT is used as the PC's operating system and a serial connection to the FastTrace is used, ensure that

the FastTrace PC Viewer software is running BEFORE the FastTrace is powered up. Correct connection will then occur.
After the first connection has been made and other re-connections are required (or the unit becomes disconnected for
any reason), then the serial cable 

must be unplugged for at least 10 seconds

. This procedure will ensure that the

FastTrace stops trying to reconnect and "locking out" the correct connection attempts by the PC Viewer software.

LED Switch

When power is first applied to the FastTrace unit, the red LED on the front of the unit will be on. Within a few seconds the
red LED should start switching on, then off, every two seconds. This signifies that the unit is going through its boot cycle
and performing its internal tests. Once the unit successfully completes its boot and test sequence, the red LED will switch

off, and remain off.
If at any time during operation, the red LED switches on and stays on, this signifies a fault with the unit and technical
support is required.

Communication Settings Override:

If for any reason, the operational Site ID, password or network address for a

FastTrace is lost, use the following procedure to temporarily restore this information.
1.  Set the FastTrace's DIP Switch 7 (on the rear panel) to the ‘

ON

’ position.

2.  Re-power the unit.

This procedure will not ‘Factory Default’ the unit.

It will only set the unit to the following settings until Dip Switch 7 is turned off
and the unit is re-powered.
Site ID (FASTRACE)                        Password (FT2222)
Network Address (192.168.1.1)       Subnet Mask (255.255.255.0)

3.  Connect a crossover network cable or the null modem (serial) cable between

the unit and a PC running the ADPRO FastTrace PC Viewer.

4.  Modify the ADPRO FastTrace PC Viewer settings (

Database / Administration

/ Site Details

) as follows:

 

(NETWORK connection) - Set 'Connection Type' = 

Network

 and 'IP

Address' = 

192.168.1.1

OR

 

(SERIAL connection) Set ‘Connection Type’ = 

PSTN

 and

‘Phone’ = 

0

5.  Connect to Site (

FASTRACE

) using the default Password (

FT2222

).

6. Go 

the 

Connection

 menu and select the 

Installer Menu

 option to display the

FastTrace's User Settings menu.

7. Change 

Site Details 

to the new SITE ID, PASSWORD and Network Address

values.

8. 

SAVE ALL CHANGES

 when exiting the User Settings menu.

9.  Reset Switch 7 to the 

OFF 

position and re-power the unit.

The FastTrace will now operate with the new Site ID, Password and Network
Address.

Summary of Contents for ADPRO FastTrace

Page 1: ...stTrace PC Viewer setup wizard will load If autorun is not enabled find and run the CD ROM file named cdmenu exe Select the Install FastTrace PC Viewer option Follow the setup wizard instructions and accept ALL the default settings Exit from the menu when finished but leave the CD ROM in the drive NOTE If using the Windows NT system on the PC please refer to the IMPORTANT NOTES section on Page 4 C...

Page 2: ...d FT2222 Connection Type PSTN Transmitter type FastTrace Hunt Group Hunt Group 0 Phone number 0 Optional Network Connection Settings If using the PC s network port instead of the serial port a crossover network cable Cat 5 must be used between the PC and the FastTrace Note this cable NOT supplied The factory TCP IP network address for the FastTrace is 192 168 1 1 The factory subnet mask address is...

Page 3: ...n must be modified to use the site names phone numbers or network addresses that match the real network Once the FastTrace settings have been configured the ADPRO FastTrace PC Viewer settings must be updated to match Setting the ADPRO FastTrace PC Viewer Telephone Dial up Connection The basic information needed to use a telephone dial up connection is entered via the Database Administration Site D...

Page 4: ...nections are required or the unit becomes disconnected for any reason then the serial cable must be unplugged for at least 10 seconds This procedure will ensure that the FastTrace stops trying to reconnect and locking out the correct connection attempts by the PC Viewer software LED Switch When power is first applied to the FastTrace unit the red LED on the front of the unit will be on Within a fe...

Reviews: