background image

ADPRO FastTrace - Quick Setup Guide

201335.06

Page 2

Vision Fire & Security

  Note that for the serial port to operate correctly, a special ‘null-modem’ software driver needs to be installed. To

install this driver, go to (Windows NT): Start/Settings/Control Panel/Modems and select the 

Add

 option.

If using Windows 2000: Control Panel/Phone & Modem options/Modems and select the 

Add

 option. When the 

Install

New Modem

 dialog box is displayed, click the 

Don't detect my modem, I will select it from a list 

checkbox, then

click 

Next

 Click 

the 

Have Disk

 button to find the software driver file at: 

CDdrive#:/install/mdmcisc2.inf 

(note that the CD-

ROM should still be in the drive)

 Click 

OK

 - the driver software should now load

 

Re-boot the PC to ensure the serial comms and modem driver changes become active

To start the FastTrace PC Viewer program, double-click the FastTrace icon               .

Accessing FastTrace for the first time:

To help users with the first time setup, a number of default settings are used in the ADPRO PC Viewer software that

must match the default factory settings found in a new FastTrace unit.

The default settings stored in the FastTrace PC Viewer for a serial port connection can be found by using the following
link: 

Database/Administration/OK/Configure Sites.

 To check the defaults, select the "

FastTrace default site

" entry and

click 

Edit. 

The default values are shown below:

Site ID 

FASTRACE

Name 

FastTrace default site

Password = 

FT2222

Connection Type 

PSTN

Transmitter type 

FastTrace

Hunt Group 

Hunt Group 0

Phone (number)

0

Optional Network Connection Settings:

If using the PC's network port (instead of the serial port), a ‘crossover’ network cable (Cat 5) must be used between the
PC and the FastTrace. (Note: this cable NOT supplied).

 

The (factory) TCP/IP 

network address

 for the FastTrace is: 192.168.1.1

 The 

(factory) 

subnet mask

 address is 255.255.255.0

To use the 

network 

connection, change the 

Site Configuration

 settings (

Database / Administration / OK / Configure

Sites

) in the ADPRO FastTrace PC Viewer to the following:

 

Connection Type = 

Network

 

IP Address = 

192.168.1.1

Before exiting the System Administration, select Configure Communications and follow the wizard to de-select the
Generic Null Modem and select the Network Adaptor.

Configuration of your PC IP properties are needed to ensure the network address and subnet mask will allow
communication with the FastTrace.

The (factory) TCP/IP 

network address

 and 

subnet mask

 for the FastTrace are class C addresses.  For the PC to be able

to successfully connect to the FastTrace, your PC IP settings will also need to be modified to a class C address.

For ease of initial setup, you must change the PC IP settings to the following:

 The 

TCP/IP 

network address

 for your PC should be set to: 192.168.1.2

 The 

subnet mask

 address should be set to: 255.255.255.0

Connecting to the FastTrace:

Ensure the FastTrace has completed its start-up checks (as indicated by the red status light going off).

 From 

the 

Connection

 menu, click the 

Connect to Site

 option

 

Select the site named 

FastTrace default site

 and click the 

OK 

button

Summary of Contents for ADPRO FastTrace

Page 1: ...stTrace PC Viewer setup wizard will load If autorun is not enabled find and run the CD ROM file named cdmenu exe Select the Install FastTrace PC Viewer option Follow the setup wizard instructions and accept ALL the default settings Exit from the menu when finished but leave the CD ROM in the drive NOTE If using the Windows NT system on the PC please refer to the IMPORTANT NOTES section on Page 4 C...

Page 2: ...d FT2222 Connection Type PSTN Transmitter type FastTrace Hunt Group Hunt Group 0 Phone number 0 Optional Network Connection Settings If using the PC s network port instead of the serial port a crossover network cable Cat 5 must be used between the PC and the FastTrace Note this cable NOT supplied The factory TCP IP network address for the FastTrace is 192 168 1 1 The factory subnet mask address is...

Page 3: ...n must be modified to use the site names phone numbers or network addresses that match the real network Once the FastTrace settings have been configured the ADPRO FastTrace PC Viewer settings must be updated to match Setting the ADPRO FastTrace PC Viewer Telephone Dial up Connection The basic information needed to use a telephone dial up connection is entered via the Database Administration Site D...

Page 4: ...nections are required or the unit becomes disconnected for any reason then the serial cable must be unplugged for at least 10 seconds This procedure will ensure that the FastTrace stops trying to reconnect and locking out the correct connection attempts by the PC Viewer software LED Switch When power is first applied to the FastTrace unit the red LED on the front of the unit will be on Within a fe...

Reviews: