Quick Setup Guide

201335.06

Page 1

Vision Fire & Security

ADPRO

®

FastTrace™

Use this guide for the first-time setup of the ADPRO FastTrace Remote Access DVR.
The setup procedure is the same for 5-channel, 10-channel and 20-channel models.

Unpack the ADPRO FastTrace and check for signs of damage. If any damage is found, 

before installation

 please report

to your supplier or to Vision Fire & Security directly.

Check the carton contents:

 ADPRO 

FastTrace

  CD-ROM containing ADPRO FastTrace PC Viewer Software

  Installation and Setup Manual

  Null-modem cable 1m (3ft)

  9-way screw terminal plug

  4x 15-way screw terminal plugs (6 supplied with Model 5020)

  IEC power cord

CHECK FACTORY DIPSWITCH SETTINGS AS SHOWN

Make sure that the unit is set to operate to the appropriate video
standard for the region, either 

PAL 

or 

NTSC

 (check DIPswitch

10 for correct position).

To complete the first time setup, you will need a PC running
Windows NT or Windows 2000, with an unused serial port or an
Ethernet Port and a CD-ROM drive.

Installing FastTrace PC Viewer Program:

Start the PC and insert the 

ADPRO FastTrace PC Viewer CD-ROM

. If the 'autorun' feature is used, the ADPRO

FastTrace PC Viewer setup wizard will load. If autorun is not enabled, find and run the CD-ROM file named

cdmenu.exe.

Select the 

Install FastTrace PC Viewer

 option. Follow the setup wizard instructions and accept ALL the default settings.

Exit from the menu when finished, but 

leave the CD-ROM in the drive

.

NOTE:

 If using the Windows NT system on the PC, please refer to the IMPORTANT NOTES section on Page 4.

Configuring the FastTrace PC Viewer & FastTrace:

The FastTrace's 

User Settings

 menu is accessed by the FastTrace PC Viewer software. Access can be made in two

ways, via the PC's serial (comms) port 

or

 via the network port.

Using the Serial Port to access FastTrace

:

When using serial port connection, the 1m (3ft) null-modem cable
(supplied) is used. (Note: should a longer cable be required, the

wiring diagram is shown on Page 3 of this guide).

 

The serial comms (COM) port on the PC must be configured for
operation as follows:
Data rate = 115,200 bps, Data bits = 8, Parity = none, Stop-bits

= 1, Flow control = hardware
Note: To change the settings on the COM ‘n’ port, go to:

Windows NT:

Control Panel / Ports / COM 'n'

Windows 2000:

Control Panel / System /
Hardware / Device Manager /

Ports / COM 'n' / Port Settings

  Ensure the FastTrace is free-standing with no obstruction to

airflow (cooling fan at rear)

 

Connect the cable between the FastTrace "COMMS 2" port and

the PC’s serial port (see diagram)

Summary of Contents for ADPRO FastTrace

Page 1: ...stTrace PC Viewer setup wizard will load If autorun is not enabled find and run the CD ROM file named cdmenu exe Select the Install FastTrace PC Viewer option Follow the setup wizard instructions and accept ALL the default settings Exit from the menu when finished but leave the CD ROM in the drive NOTE If using the Windows NT system on the PC please refer to the IMPORTANT NOTES section on Page 4 C...

Page 2: ...d FT2222 Connection Type PSTN Transmitter type FastTrace Hunt Group Hunt Group 0 Phone number 0 Optional Network Connection Settings If using the PC s network port instead of the serial port a crossover network cable Cat 5 must be used between the PC and the FastTrace Note this cable NOT supplied The factory TCP IP network address for the FastTrace is 192 168 1 1 The factory subnet mask address is...

Page 3: ...n must be modified to use the site names phone numbers or network addresses that match the real network Once the FastTrace settings have been configured the ADPRO FastTrace PC Viewer settings must be updated to match Setting the ADPRO FastTrace PC Viewer Telephone Dial up Connection The basic information needed to use a telephone dial up connection is entered via the Database Administration Site D...

Page 4: ...nections are required or the unit becomes disconnected for any reason then the serial cable must be unplugged for at least 10 seconds This procedure will ensure that the FastTrace stops trying to reconnect and locking out the correct connection attempts by the PC Viewer software LED Switch When power is first applied to the FastTrace unit the red LED on the front of the unit will be on Within a fe...