GENERAL MAINTENANCE & LAMP REPLACEMENT
•
A convenient power switch is located on the device and should be turned off before
any maintenance.
•
To clean, UVC lamps and reflector surfaces can be wiped down with a soft, lint free
cloth and isopropyl alcohol.
•
UVC lamps should be replaced and changed annually or every 9,000 hours of
operation to maintain maximum output and effectiveness.
•
To replace lamps:
1.
Obtain the correct replacement lamp for your model.
2.
Disconnect equipment from power source.
3.
Allow lamp to cool down at least 10 minutes before removing. Personal
injury may result otherwise.
4.
Carefully remove the used UVC lamp and replace with the new lamp. Refer
to the Lamp Installation Instructions above listed 1 through 8. See
Figure 2
.
•
For broken lamps and proper disposal, follow your local safety information
regarding hazardous waste and material related to broken lamps.
https://www.epa.gov/cfl/cleaning-broken-cfl
Figure 6