UVC LAMP INSTALLATION
1.
Make sure the disinfection system is disconnected from any power source before
installing the UVC lamps.
2.
When handling UVC lamps, wearing lint free gloves is strongly advised. Oils from
skin contact can reduce lamp life and output if not removed prior to installation.
3.
Remove the lamps from their protective sleeves.
4.
Clean each lamp prior to installation to maximize the efficiency of use and lamp life.
Use isopropyl alcohol and a soft cotton cloth to wipe dust and fingerprints from the
lamp.
5.
Gently insert the lamp into the lamp holder / tombstone and secure the lamps into
position on the lamp sockets by rotating the lamp until the lamp holder / tombstone
locks.
6.
To complete installation, replace the wire guard and secure the securing clips to the
housing.
7.
A soft, lint free cloth can be used to wipe off the reflector and lamp area to remove
any dirt, dust or fingerprints after installation.