background image

 

 

UVCM8320254WH  

UV-C MOBILE  

 

 

 

 

 

 

 

Page 3 

 
XtraLight Manufacturing, LTD.    8812 Frey Rd. Houston, TX 77034  (800) 678-6960 F (713) 943-2818    

www.XLM.com

 

  

For visual aids, please visit our 

 YouTube Channel 

 

 

UVC LAMP INSTALLATION 

1.

 

Make sure the disinfection system is disconnected from any power source before 
installing the UVC lamps.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

 

When handling UVC lamps, wearing lint free gloves is strongly advised. Oils from 
skin contact can reduce lamp life and output if not removed prior to installation. 

3.

 

Remove the lamps from their protective sleeves. 

4.

 

Clean each lamp prior to installation to maximize the efficiency of use and lamp life. 
Use isopropyl alcohol and a soft cotton cloth to wipe dust and fingerprints from the 
lamp. 

5.

 

Gently insert the lamp into the lamp holder / tombstone and secure the lamps into 
position on the lamp sockets by rotating the lamp until the lamp holder / tombstone 
locks.   

6.

 

To complete installation, replace the wire guard and secure the securing clips to the 
housing. 

7.

 

A soft, lint free cloth can be used to wipe off the reflector and lamp area to remove 
any dirt, dust or fingerprints after installation. 

 
 
 
 
 
 

Figure 2 

For more infomation on 

UV-C Systems

Summary of Contents for UV-C MOBILE

Page 1: ...ORMATION This product emits 254 nm wavelength of UVC energy The mobile system is a germicidal ultraviolet system that is intended to disinfect high touch surfaces and areas CAUTION Observe basic safety precautions including the use of personal protective equipment PPE while operating and handling the system Please read and follow all instructions warnings and safety notices Do not expose skin or e...

Page 2: ...y any room with this device while it is in operation WARNING Burn Hazard Unplug the power source before replacing lamps Allow lamps to cool down at least 10 minutes before removing them Personal injury may result otherwise WARNING Mercury Hazard Do not break UVC lamps Each UVC lamp contains small amounts of mercury that can have harmful effects if exposed or ingested o Exposure to mercury may caus...

Page 3: ...3 Remove the lamps from their protective sleeves 4 Clean each lamp prior to installation to maximize the efficiency of use and lamp life Use isopropyl alcohol and a soft cotton cloth to wipe dust and fingerprints from the lamp 5 Gently insert the lamp into the lamp holder tombstone and secure the lamps into position on the lamp sockets by rotating the lamp until the lamp holder tombstone locks 6 T...

Page 4: ...o a compatible power source and turn on primary system power A visual indicator will notify that a power source has been connected 4 The secondary power switch Is connected to an occupancy sensor The WiFi enabled smart switch allows for remote system control through app connectivity The app is compatible with both Android and IOS and can be downloaded at my leviton com Google Play or the Apple Sto...

Page 5: ...UVCM8320254WH UV C MOBILE Page 5 XtraLight Manufacturing LTD 8812 Frey Rd Houston TX 77034 800 678 6960 F 713 943 2818 www XLM com Figure 4 ...

Page 6: ...ng the adjustment settings recommendations See Figure 5 for custom settings instructions 7 Direct the UVC energy towards specified areas and apply the recommended dosage information required 8 Use the Dosimeter cards to validate dosage and a visual indicator of UVC delivered onto the target area The sensor instructions and My Leviton App Guide can be downloaded from our website https www xtralight...

Page 7: ...y or every 9 000 hours of operation to maintain maximum output and effectiveness To replace lamps 1 Obtain the correct replacement lamp for your model 2 Disconnect equipment from power source 3 Allow lamp to cool down at least 10 minutes before removing Personal injury may result otherwise 4 Carefully remove the used UVC lamp and replace with the new lamp Refer to the Lamp Installation Instruction...

Page 8: ...er information regarding XtraLight s recommended steps for disinfection please visit https blog xtralight com uv dosage for disinfection UV C QUESTIONS ADDITIONAL INFORMATION Contact our Customer Service department at 800 678 6960 or email customerservice xlm com Visit https info xtralight com en us uvc ultraviolet disinfection system FAQ https info xtralight com faq ultraviolet disinfection syste...