background image

8

1

2

3

4

8

9

5

7

6

U S E R S

Present master TAG

Press 2

Present TAG within 10 sec

6.2 MEMORIZING SERVICE TAGS

Press 1

Press  1

Press E (LED flash alternately) 

Memorization

of SERVICE TAG 

TAG 

already memorized 

as MASTER

TAG 

already memorized 

as SERVICE

The system returns to point 6. To exit, press "E" or wait 20 sec. (timeout). 

ATTENTION:

 if you try to memorize a service TAG before you have memorized at least one master TAG, the TAG will 

automatically be memorized as a master.

Activate the escutcheon

Press 1 then holding down 1 press E

SERVICE TAGS, if inserted, 

are disabled

99334GB - FINGERPRINT READER  - REV. 02

Summary of Contents for 99.729

Page 1: ... manufacture shipping costs to and from service centers are charged to the customer In case of a repeated malfunction of the same origin or a malfunction that cannot be repaired Mottura Serrature di Sicurezza S p A may decide in its final judgment to replace the entire device The warranty on the replacement device will continue to the expiration of the original device If the device must be service...

Page 2: ... place your finger the same way it was recorded during memorization The scanner is programmed to work with a certain degree of security during the scan and will always recognize only the same portion of skin scanned during memorization Therefore a different finger swipe will NOT be memorized During memorization and scanning place your finger slowly with moderate pressure Keep it flat and never cur...

Page 3: ...OT tied to the escutcheon but to the device to which it is connected XMODE protected tag system 255 TAG XMODE free tag system 200 TAG XNOVA ELECTRONIC ELECTRICAL LOCKS 200 TAG The function keys are numeric buttons 1 2 E to be used during programming The LED show door state on any operation under way RED LED flashing lock closed RED LED on lock closing GREEN LED flashing lock open GREEN LED on lock...

Page 4: ...ELECTRONIC ELECTRICAL XNOVA LOCKS To connect the escutcheon to XNova or other electronic electrical locks use an interface card RELAY MODULE Art 99724 with MAIN POWERED Art 99746 with MAIN POWERED and BATTERY to be purchased separately See the article s instruction manual WITH XMODE ELECTRONIC LOCKS I N S T A L L E R 99334GB FINGERPRINT READER REV 02 Internal escutcheon Cable 99 699 Cable 99 698 P...

Page 5: ...E ONLY THE EXTERNAL ESCUTCHEON The system automatically exits programming mode If the lock is new or has been reset any free Mottura TAG can be used to enter programming mode and open the lock One or more master TAGS SHOULD BE MEMORIZED immediately to guarantee security See the lock user manual chapter 5 for memorization and management of TAGS Activate the escutcheon Press 1 then holding down 1 pr...

Page 6: ...tion and to guarantee maximum security This procedure DELETES all previous fingerprints any test fingerprints that may open the lock without authorization KEEP THE DOOR OPEN The system automatically exits programming mode Press SET UP button Press E Repeat the operations I N S T A L L E R Activate the escutcheon Press 1 then holding down 1 press E 99334GB FINGERPRINT READER REV 02 NO ...

Page 7: ...emorized TAGS Present master TAG 1 Present TAG 2 within 10 sec 6 1 MEMORIZING MASTER TAGS Press 1 Press 1 Press E LED flash alternately Memorization MASTER TAG TAG already memorized as MASTER TAG already memorized as SERVICE The system returns to point 6 To exit press E or wait 20 sec timeout SERVICE TAGS if inserted are disabled 5 MANAGING TAGS WITH XMODE ATTENTION See the lock user manual chapte...

Page 8: ...memorized as MASTER TAG already memorized as SERVICE The system returns to point 6 To exit press E or wait 20 sec timeout ATTENTION if you try to memorize a serviceTAG before you have memorized at least one masterTAG theTAG will automatically be memorized as a master Activate the escutcheon Press 1 then holding down 1 press E SERVICE TAGS if inserted are disabled 99334GB FINGERPRINT READER REV 02 ...

Page 9: ... TAGS DISABLED The system returns to point 6 To exit press E or wait 20 sec timeout Present master TAG Press 1 Press E LED flash alternately Activate the escutcheon Press 1 then holding down 1 press E Press 1 then holding down 1 press E SERVICE TAGS if inserted are disabled ...

Page 10: ... 1 Press E LED flash alternately SERVICE TAGS ENABLED The system returns to point 6 To exit press E or wait 20 sec timeout Activate the escutcheon Press 1 then holding down 1 press E Press 1 then holding down 1 press 2 SERVICE TAGS if inserted are disabled 99334GB FINGERPRINT READER REV 02 ...

Page 11: ...econds Press E LED flash alternately The system returns to point 6 To exit press E or wait 20 sec timeout Present TAG within 10 sec TAG deleted Unknown TAG ATTENTION You CANNOT delete the master TAG used to enter programming mode Press E Activate the escutcheon Press 1 then holding down 1 press E 3 sec ...

Page 12: ...ss 1 Press E LED flash alternately The system returns to point 6 To exit press E or wait 20 sec timeout TAGS being deleted Press 2 for 3 seconds Press 1 then holding down 1 press E Activate the escutcheon Press 1 then holding down 1 press E 99334GB FINGERPRINT READER REV 02 3 sec ...

Page 13: ...MEMORIZING FINGERPRINTS XMODE ELECTRONIC ELECTRICAL XNOVA LOCKS ENTER PROGRAMMING MODE KEEP THE DOOR OPEN AND USE ONLY THE EXTERNAL ESCUTCHEON Present master TAG Press E LED flash alternately Press 1 Place your finger first time Place your finger second time Activate the escutcheon Press 1 then holding down 1 press E Place your finger third time Maximum limit of finger prints inserted 32 NO ...

Page 14: ... USE ONLY THE EXTERNAL ESCUTCHEON delete ALL fingerprints The system returns to point 5 To exit press E or wait 20 sec timeout Present master TAG Press E LED flash alternately Press 2 LED flash alternately then holding down 2 press E Press E for 3 seconds Activate the escutcheon Press 1 then holding down 1 press E 99334GB FINGERPRINT READER REV 02 ...

Page 15: ...scutcheon and if recognized the imprint opens the lock Escutcheon not authenticated with lock LED flash alternately After you have stored the fingerprints you can use them to operate the lock fingerprint valid scanning error or unknown fingerprint In case of failed scan see page 2 USING THE FINGERPRINT READER NO ...

Page 16: ...www mottura it 99334GB 04 17 a_017329 ...

Reviews: