d)
When not in use, idle tools should be stored in a place out of reach of visitors and children.
e)
Maintain careful manipulation with the tool. Check for deflecting or jamming of turning parts, damaged
parts or other conditions which may influence operating with the tool.
f)
Keep tools sharp and clean for better and safer performance. Properly serviced tools are less likely to
become covered in impurities and are better controlled.
g)
Use equipment recommended by the producer of your model only. Modifications and accessories used at
one tool may be dangerous when used with another model.
Warranty does not apply for accessories!
USING
Keep wor area clean and dry before using, expecially keep away from the dusty
condition. If not, you should increase filter.
Check the air compressor for blockage and whether all the spare aprt is normal of
not before using. Plug the power cord into an electrical outlet with a grounding
plug. Close the air control valve and pull up on the power switch to turn on before the motor started.
When index of the pressure indicator rise to the set max pressure valve, the control switch will off
automatically. When the machines stop working, the solenoid valve will remove the air in the tank. Mare sure
that the machine get started after the pressure inside the tank reach to the mini control point.
Connect the high pressure air hose to the air outlet. Open the air outlet valve to the middle position to allow
the air to pass. The pressure control will turn off automativally when the pressure indicator shows the
pressure fall to the set mini valve, and then the machines restart. (The max pressure and mini pressure value is
set before the machines out of factory, it´s not neccessary to adjust the set value by yourself.
If the voltage of the user too low and not within the rang of +/- 10%, the machines cant´t be connected to the
power supply.
You need to add the power regulator to make the voltage to reach the standard voltage value.
Empty the air and condensation. In the process of use, there will be a handle of condensation. It must be used
daily to release all trapped air and moisture through the drain valve which is located under the tand. Make
sure to push down on the power switch to turn the compressor off and release the air int the tank before
turning on the drain valve. Close the valve after releasing.
Disinfect the air filter. In the process of use, some dust gets into the air filter. it must be used daily to disinfect
the air filter. Make sure to push down on the pressure switch to turn the compressor off and then screw tha ir
filter, get out of the spongle and wash, dry it, reistall the ari filter.
There is an screw inside the pressure controller for ajust the pressure, Don´t adjust the pressure by xourself as
the pressure is set before xout of factory, or it will damage the unit or case the machine can,t operate properly.
TROUBLE AND REMEDIES
Summary of Contents for HK550-9