5.
Configuration command based on authentication mode
GD.LINK>
enable
\\Access privilege mode
Password:
admin
\\Enter Password
GD.LINK#
con t
\\Access overall configuration mode
GD.LINK(config)#
service stop
\\Stop NC forwarding
GD.LINK(config)#
headend
\\Access head-end configuration mode
GD.LINK(config-headend)#
authentication on
\\Start authentication mode, when this mode start, all
terminal CPEs must be configured manually again,
otherwise CPEs can not be connected (shut down by
default allows all CPEs’ accesses).
GD.LINK(config-headend)#
exit
\\Exit head-end mode
GD.LINK(config)#
service start
\\Start NC forwarding
GD.LINK(config)#
user 1
\\Permit access CPE’s ID number
GD.LINK(config-user 1)#
uid xx:xx:xx:xx:xx:xx
\\Permit access CPE’s MAC number
GD.LINK(config-user 1)#
cpe-port 1 enable
\\Enable to set up CPE port 1
GD.LINK(config-user 1 )#
cpe-port 1 access-vlan xx
\\Set up VLAN of CPE port 1
GD.LINK(config-user 1)#
end
\\Exit to privilege mode
GD.LINK#
show run
\\Check configuration
GD.LINK#
write
\\Save Configuration
6.
Change login password
GD.LINK>
enable
\\Access privilege mode
Password:
admin
\\Enter password admin
GD.LINK#
con t
\\Access
overall
configuration mode
GD.LINK(config)#
enable password xxx
\\ Enable Configure password
GD.LINK(config)#
end
\\Exit to privilege mode
GD.LINK#
write
\\Save configuration
7.
Loop detection
GD.LINK>
enable
\\Access privilege mode
Password:
admin
\\Enter password admin
GD.LINK#
con t
\\Enter overall configuration mode
GD.LINK(config)#
loopdetect enable
\\Start loop detection (default is shut down
GD.LINK(config)#
end
\\Exit to privilege mode
GD.LINK#
write
\\Save configuration
8.
Check bit error rate
GD.LINK>
enable
\\Enter privilege mode
Password:
admin
\\Enter password admin
GD.LINK#
show on
\\Check online CPE