background image

 
 

5.

Configuration command based on authentication mode 

 

GD.LINK> 

enable

             

 

\\Access privilege mode

 

Password: 

admin                 

\\Enter Password

 

GD.LINK# 

con t   

               

\\Access overall configuration mode

 

GD.LINK(config)# 

service stop           

\\Stop NC forwarding

 

GD.LINK(config)# 

headend                 

\\Access head-end configuration mode

 

GD.LINK(config-headend)#

 authentication on   

\\Start authentication mode, when this mode start, all   

terminal CPEs must be configured manually again,   

otherwise CPEs can not be connected (shut down by   
default allows all    CPEs’ accesses). 

GD.LINK(config-headend)# 

exit     

 

\\Exit head-end mode

 

GD.LINK(config)# 

service start     

  

\\Start NC forwarding

 

GD.LINK(config)# 

user 1                   

\\Permit access CPE’s ID number

 

GD.LINK(config-user 1)# 

uid xx:xx:xx:xx:xx:xx             

\\Permit access CPE’s MAC number

                                          

 

GD.LINK(config-user 1)# 

cpe-port 1 enable       

 

       

\\Enable to set up CPE port 1 

                                          

 

GD.LINK(config-user 1 )# 

cpe-port 1 access-vlan xx     

\\Set up VLAN of CPE port 1

                                         

 

GD.LINK(config-user 1)# 

end         

                                   

\\Exit to privilege mode

 

GD.LINK#

 show run                                                 

     

 \\Check configuration

 

GD.LINK#

write                                       

                               

\\Save Configuration

 

 

6.

 

Change login password 

GD.LINK> 

enable

                               

 \\Access privilege mode

 

Password:

admin                                 

 \\Enter password admin

 

GD.LINK# 

con t   

                                 

\\Access

 overall

 configuration mode

 

GD.LINK(config)# 

enable password xxx     

  

\\ Enable Configure password

 

GD.LINK(config)#

end                                   

  

 \\Exit to privilege mode

 

GD.LINK#

write                                                 

 

 \\Save configuration

 

       

 

7.

 

Loop detection 

GD.LINK> 

enable

                           

   

 \\Access privilege mode

 

Password:

admin                                 

 

 \\Enter password admin 

GD.LINK# 

con t   

                           

    

\\Enter overall configuration mode

 

GD.LINK(config)#

 

loopdetect enable 

 

\\Start loop detection (default is shut down 

GD.LINK(config)#

end                         

  

\\Exit to privilege mode

 

GD.LINK#

write                                   

  

 \\Save configuration

 

         

8.

 

Check bit error rate 

GD.LINK> 

enable

                     

  

\\Enter privilege mode

 

Password:

admin                     

  

 \\Enter password admin 

GD.LINK# 

show on   

           

   

 \\Check online CPE 

Summary of Contents for XL-MB103SW

Page 1: ...XL MB103SW MoCA Ethernet bridge User s Guide ...

Page 2: ...xample in a community VOD service is VLAN 100 IP service is VLAN 200 and if CPE s port 1 and port 3 are equipped for VOD service port 2 and port 4 are equipped for IP service the configuration should be made as bellow GD LINK enable access initial mode Password admin enter password GD LINK configure terminal enter overall configuration mode GD LINK config cpe template enable open the template conf...

Page 3: ...te enable cpe template 8021q on cpe template port 1 enable cpe template port 1 access vlan 100 cpe template port 2 enable cpe template port 2 access vlan 200 cpe template port 3 enable cpe template port 3 access vlan 100 cpe template port 4 enable cpe template port 4 access vlan 200 end configure terminal interface manage interface exit end configure terminal port coax exit end configure terminal ...

Page 4: ...D LINK config interface manage interface access interface configuration mode GD LINK config if ip address 10 86 5 100 22 gateway 10 86 4 1 configure IP address to be 10 86 5 100 22 represents the subnet mask bits 10 86 4 1 is default gateway address GD LINK config if vlan 52 configure the management VLAN as Vlan 52 GD LINK config if end back to privilege configuration mode GD LINK write save the c...

Page 5: ... finished program configure terminal exit configure terminal end configure terminal interface manage interface exit end configure terminal port coax exit end configure terminal headend frequency 1100 exit end This configuration is mainly for solving the basic interference problems Use show online command under NC to observe whether the NC s attenuation value is in a normal range or not If the forw...

Page 6: ...r 1 cpe port 1 enable Enable to set up CPE port 1 GD LINK config user 1 cpe port 1 access vlan xx Set up VLAN of CPE port 1 GD LINK config user 1 end Exit to privilege mode GD LINK show run Check configuration GD LINK write Save Configuration 6 Change login password GD LINK enable Access privilege mode Password admin Enter password admin GD LINK con t Access overall configuration mode GD LINK conf...

Page 7: ...CPE MAC Add Forwarding rate Receiving Rate Actual Attenuation Error Packet Number ...

Reviews: