15
Figure 2
Figure-3 is the connection diagram of the connection between door phone and electric
lock.
Figure 3
It is a transformer power supply, 220V AC is to be connected to L and N respectively
to transform and then output 12 DC in order to supply power for the door phone and
electric lock. The electric lock has four binding posts, two are power-supply binding posts,
and the other two are unlock binding posts. There are four terminals in the unlock interface
area of the door phone, namely, COM terminal, NC (electricity-on unlock), NO (electricity-off
unlock) and GND. Connect the L+ of the electric lock to the DC 12V positive pole; L- to the
NO; then the COM to DC 12V negative pole.
Note:
1.
The power-supply cable RVV2*1.0 is adopted for the door phone and electric
lock both.
2.
User can select either NC or NO to connect according to actual requirements.