DIP Switches Setting

The DIP switch is designed to set the code 

for door station and monitor, there are two 

states for each DIP switch, please refer to 

the sketch map.

ON(1)

=

OFF(0)

=

ON

ON

Total 2 bits can be configured, bit-1 and bit-2 are used to assign ID code for door sta-

tion.The switches can be modified either before or after installation.

There are 6 bits in total. The DIP switches are used to configure the user code 

for Monitors.

Bit-6 is an video impedance match switch, which have to be set to ON if match 

the impedance, otherwise set to OFF. 

Bit-1~Bit-5 are used to set user code, for DT597 door station, the user code 

should be set to 0~15.

Please refer to the following settings:

Door station DIP setting

Indoor monitor DIP setting

Bit state

 Descriptions

Default setting, ID = 0(00), set to the first Door Station.

ID = 1(10), set to the second Door Station.

ID = 2(01), set to the third Door Station.

ID = 3(11), set to the fourth Door Station.

1 2

ON

1 2

ON

1 2

ON

1 2

ON

-10-

Summary of Contents for DPC-D247

Page 1: ...DPC D247 2 wired door station User s manual...

Page 2: ...ization The call button is made of durable zinc alloy with white backlight for illumination The name label with orange backlight is covered by a fully secured and flameproof glass plate Parts and Func...

Page 3: ...power positive power S1 S2 Lock power output to connect 2 locks S Lock power output Door Station Mounting OPEN CLOSE 90 1 2 3 4 Adjusting Camera Angle Use a screwdriver to loosen the screw and then a...

Page 4: ...Open Close 1 2 3 System Wiring and Connections L1 L2 PL S1 S2 S monitor AC PC6 Basic one to one Connection Steps 1 Use the special spanner to move 900 to loosen the screw 2 Open the front panel 3 Ins...

Page 5: ...tton EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default EB LOCK LOCK 2nd 1ST 2nd EB 1ST Jumper position in Connect two locks 2 3 1 2 3 BUS PL S1 S2 S EB LOCK BUS PL S1 S2 S Jumper p...

Page 6: ...Code Number 0010 Remove all remote control 0011 Add remote control 8000 Set as master unit 0 8001 Set as slaver unit 1 8002 Set as slaver unit 2 8003 Set as slaver unit 3 8004 Set as guard unit 8005...

Page 7: ...ches are used to configure the user code for Monitors Bit 6 is an video impedance match switch which have to be set to ON if match the impedance otherwise set to OFF Bit 1 Bit 5 are used to set user c...

Page 8: ...1 4 ACS 4T image sensor with DSP processor Lock Power supply 12Vdc 300mA Internal Power Working temperature 10 C 45 C Dimension 188 H 110 W 34 D mm Precautions Please clean the unit with soft cotton c...

Reviews: