5.2.3 Unlock parameter setting(set on monitor)

1.Touch 

 item on main 

menu page.

2.Touch the screen anywhere and 

hold for 2s.

3.Touch Installer setup item

4.A digital keypad and setting 

instructions will be shown.

Manual

Monitor

Monitor

Memory 

Playback

Album

User Setup

09/30/2010  Thu.16:41

Close

Intercom

Multimedia

H/W :                                               ---      a1.3      
S/W:                                        V17.11.418.00
Local addr:                                                 ---
Unlock timing:                                          ---
Video standard:                                         -
UI-CODE:                                                   ---
MCM-VER.:                                                ---
Updated:                                                   ---

Home

Installer

setup

Caliber

TouchScreen

Code Number:[----]

[0010]#:Remove all remote control

[0011]#:Add remote control
[8000]#:Set as master unit 0

[8001]#:Set as slaver unit 1

[8002]#:Set as slaver unit 2

[8003]#:Set as slaver unit 3

[8004]#:Set as guard unit

[8005]#:Set as not guard unit

[8006]#:Panel on as slaver unit called

[8007]#:Panel off as slaver unit called

[8008]#:Date format:MM/DD/YYYY

[8009]#:Date format:DD/MM/YYYY

[8010]#:Set lock mode to 0

[8011]#:Set lock mode to 1
[8021]~[8029]

          #Set the lock time of 1~9s
Multi language settings:

---

1
4
7

8
0

9

6

5

2

3

Cancel

Installation settings:

Note:

1.must connect correctly before setting.

2.the parameter will be saved in door station automatically,so you need only 

set on one monitor.

3.the above diagram is fit for icon menu series monitors only, to text menu se

-

ries monitors,please refer to the corresponding user manual.

-9-

Summary of Contents for DPC-D247

Page 1: ...DPC D247 2 wired door station User s manual...

Page 2: ...ization The call button is made of durable zinc alloy with white backlight for illumination The name label with orange backlight is covered by a fully secured and flameproof glass plate Parts and Func...

Page 3: ...power positive power S1 S2 Lock power output to connect 2 locks S Lock power output Door Station Mounting OPEN CLOSE 90 1 2 3 4 Adjusting Camera Angle Use a screwdriver to loosen the screw and then a...

Page 4: ...Open Close 1 2 3 System Wiring and Connections L1 L2 PL S1 S2 S monitor AC PC6 Basic one to one Connection Steps 1 Use the special spanner to move 900 to loosen the screw 2 Open the front panel 3 Ins...

Page 5: ...tton EB 4 The Unlock Mode Parameter of Monitor must be set to 0 by default EB LOCK LOCK 2nd 1ST 2nd EB 1ST Jumper position in Connect two locks 2 3 1 2 3 BUS PL S1 S2 S EB LOCK BUS PL S1 S2 S Jumper p...

Page 6: ...Code Number 0010 Remove all remote control 0011 Add remote control 8000 Set as master unit 0 8001 Set as slaver unit 1 8002 Set as slaver unit 2 8003 Set as slaver unit 3 8004 Set as guard unit 8005...

Page 7: ...ches are used to configure the user code for Monitors Bit 6 is an video impedance match switch which have to be set to ON if match the impedance otherwise set to OFF Bit 1 Bit 5 are used to set user c...

Page 8: ...1 4 ACS 4T image sensor with DSP processor Lock Power supply 12Vdc 300mA Internal Power Working temperature 10 C 45 C Dimension 188 H 110 W 34 D mm Precautions Please clean the unit with soft cotton c...

Reviews: