DIP Switch Setting

 

 

The DIP switch is designed to set the code for door station and monitor, there are two states for 

each DIP switch, please refer to the following sketch map.

 

 

ON(1) 

 

 

OFF(0) 

 

 

 

 

 

Door station DIP setting

 

 

Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station, bit-3 is 
used to match the video impedance.The switches can be modified either before or after installation.

 

 

 

Bit state

 

 

Description

 

ON 

 

1  2 

3

 

 

ID = 0(00), set to the first door station

 

ON 

 

1  2 

3

 

 

ID = 1(10), set to the second door station

 

ON 

 

1  2 

3

 

 

ID = 2(01), set to the third door station

 

ON 

 

1  2 

3

 

 

ID = 3(11), set to the fourth door station

 

 

Note: if the video impedance need to match, please set the bit-3 on.

 

 

 
 

Indoor monitor DIP setting

 

 

There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.

 

 

Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance,

 

otherwise set to OFF.

 

Bit-1~Bit-5 are used to set user code, to 

DPC-D246A

 door station, the user code should set to 

0~15. Please refer to the following settings:

 

Summary of Contents for DPC-D246A

Page 1: ...2 Wire Video Intercom System DPC D246A User s manual...

Page 2: ...Front Panel Call Button Microphone Rainy Cover Terminal Description Lock Control Jumper SPK adjust Connection line DIP PROG ON 1 2 3 CALL button O N 1 2 3 BUS Blue Green S2 Red PL White S1 Yellow S1 B...

Page 3: ...a screwdriver T20 one M4X10 screw two PA4X25 screws three PA3x25 screws three PM3x12 screws and five screw stoppers 6X30 Installation steps Installation height for door station usually is 145 160cm 1...

Page 4: ...L S2 S1 S1 Bus PL S2 S1 S1 DIP on off off A B C D AC DBC 4S PC6 OFF ON Impedance Switch BUS Blue Green S2 Red PL White S1 Yellow S1 Black Multi Monitors Connection Basic IN OUT wiring mode ON ON ON ON...

Page 5: ...mpedance switch OFF ON ON 1 2 3 4 5 6 Code 13 DIP 6 on monitor ON 1 2 3 4 5 6 Code 12 DIP 6 on monitor DIP on off off ON 1 2 3 4 5 6 Code 3 DIP 6 on monitor ON 1 2 3 4 5 6 Code 2 DIP 6 on monitor Impe...

Page 6: ...ronic lock of Power on to unlock type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock...

Page 7: ...ion ON 1 2 3 ID 0 00 set to the first door station ON 1 2 3 ID 1 10 set to the second door station ON 1 2 3 ID 2 01 set to the third door station ON 1 2 3 ID 3 11 set to the fourth door station Note i...

Page 8: ...ck Power Supply 12Vdc 300mA Internal Power Working Temperature 10 C 45 C Wiring 2 wires non polarity Dimension 137 H x49 W x28 D mm Precaustions Please clean the unit with soft cotton cloth don t use...

Page 9: ...ferent cables may also affect the maximum distance which the system can reach The farest monitor monitor with two or four monitors monitor monitor DBC 4S B C AC PC6 When Monitor quantity 20 A When Mon...

Page 10: ......

Reviews: