3
Directly connect 2 electronic locks to the door station and use the Camera power to supply the locks. There are 2
separate unlock icons on Monitor for opening each lock. Note that the 2 locks should be the same safety type.
Use external power supply to power the lock, in this way, wide range lock from 5V to 48V locks can be used in the
system. Note that in this case, the Lock Control Jumper is removed in both lock type.
1
2
O
N
to Monitor
-
+
BUS PL S1+ S2+ S-
BUS PL S1+ S2+ S-
-
+
The lock consumption must not
greater than 12V 500mA.
Electromechanical lock
Connection for Electromechanical lock
Connection for Electromagnectical lock
lock #2
lock #2
lock #1
lock #1
1
2
O
N
to Monitor
-
+
The lock consumption must not
greater than 12V 300mA.
Electronmagnetical lock
-
+
1 2 3
Jumper position in 1-2
Unlock Mode
0: power-on-to-open
1: power-off-to-open
CALL
UNLOCK
TALK/MON
IN-USE
MENU
1 2 3
Jumper position in 2-3
Unlock Mode
0: power-on-to-open
1: power-off-to-open
CALL
UNLOCK
TALK/MON
IN-USE
MENU
1
2
O
N
1 2 3
to Monitor
-
-
+
+
BUS PL S1+ S2+ S-
BUS PL S1+ S2+ S-
Jumper removed
The lock consumption must not
greater than 48V 1.5A.
1
2
O
N
1 2 3
to Monitor
-
+
Jumper removed
The lock consumption must not
greater than 48V 1.5A.
Electronmagnetical lock
Adaptor
- +
Unlock Mode
0: power-on-to-open
1: power-off-to-open
CALL
UNLOCK
TALK/MON
IN-USE
MENU
Unlock Mode
0: power-on-to-open
1: power-off-to-open
CALL
UNLOCK
TALK/MON
IN-USE
MENU
Electromechanical lock
Connection for Electromechanical lock
Connection for Electromagnectical lock
Inner Power 2 Locks Connection