UK_AutoMixers_V2.doc
Rev 2.0
9
SPECIFICATIONS ( AMA 3150-AMA 3250-AM 3000-AM 3008)
AMA 3150
AMA 3250
AM 3000
AM 3008
Output power RMS
150W
50V, 70V, 100V
250w
50V, 70V, 100V
--------------------------
---------------------------
Output power IHF
225W
50V, 70V, 100V
375W
50V, 70V, 100V
--------------------------
---------------------------
Consumption:
200VA
300VA
20VA
20VA
Dimensions (WxHxD):
436 (Rack482)x132x304
436 (Rack482)x132x254
Weight (Kg):
12
14
2,5
2,5
CONTROLS AND FUNCTIONS (as per Fig.1a, 1b e 1c)
1. GAIN – gain adjustment.
2. NC
3. TREBLE – treble adjustment.
4. MID – mid adjustment.
5. BASS - bass adjustment.
6. OVER – Led for channel overload indication
7. GATE - led indication of open channel.
8. LEVEL – MIC/LINE input volume.
9. BASS – CD/TAPE channel bass adjustment.
10. TREBLE - CD/TAPE channel treble adjustment.
11. TAPE – led indication of input TAPE selection.
12. CD – led indication of input CD selection.
13. CD/TAPE switch selector
14.
LEVEL – CD/TAPE channel input volume.
15. MASTER – main volume.
16. VU meter – audio output level indicator.
17. IN/OUT – equalizer selector.
18. EQUALIZER – microphone main equalizer.
19. LOUDSPEAKER – speaker lines selector.
20. POWER – ON/OFF switch.
21. MAINS - 230 V~ supply mains socket, with protection fuse of CA mains.
22. TAPE REC - stereo output for audio recorder.
23. TAPE PLAY - stereo input for audio recorder.
24. CD - compact disc input.
25. PHANTOM / LOW FILTER – Micro-switch to connect 48 VCC phantom supply to inputs and
insert low-cut filter.
26. MICRO 1÷8 – micro/line input
27. ANTILARSEN SEND - output for external sound processing unit.
28. ANTILARSEN RETURN – input from external sound processing unit.
29. GND LIFT / BY-PASS - Micro-switch to connect electrical mass to chassis, and to by-pass
SEND / RETURN connections for antilarsen.
30. PRE OUT – mixed output of “pre” sector of amplifier.
31. VCA REMOTE VOLUME (option) – remote volume control connector
32. REMOTE LOGIC (option)– remote logic circuit control connector
33. PROGRAMS LOGIC(option) – Micro-switch for logic function programs selector.
34. LINK IN – input to extend the number of microphonic input by the AM 3008.
35. POWER OUT – direct speaker lines output.
36. LOUDSPEAKER ZONE OUT – loudspeaker lines output with zone selection
37. LINK OUT – output to connect AM 3008 to amplified mixer or mixer.