![XTA G2 Operator'S Manual Download Page 25](http://html1.mh-extra.com/html/xta/g2/g2_operators-manual_889785025.webp)
G2
Operators Manual
Page 25
Gate and Expand
MODE
Pressing and
HOLDING
the
MODE
key will change the operation of the channel
between gate and expand modes. The major differences between these are
explained below
Gate mode
In Gate mode, once the signal has dropped below the threshold,
it will be attenuated by a fixed amount, as set with the range
control. How fast this attenuation is applied is controlled by the
release control. The gate can be set to stay open for a fixed time
after dropping below the threshold –this is the hold time. How
fast the signal reaches zero attenuation again when it goes over
the threshold is determined by the attack control.
Expander mode
In Expander mode, once the signal has dropped below the
threshold, it will be gradually attenuated with a ratio as set with
the ration control. For example, if the ratio is set to 4:1, for
every dB the signal drops below the threshold, it will be
attenuated to a ¼ of its normal value.
How fast this attenuation is applied is controlled by the release
control. How fast the signal reaches zero attenuation again when
it goes over the threshold is determined by the attack control. The hold control has
no affect
in expander mode.
STEREO
Linking
Pressing and
HOLDING
the
STEREO
key will illuminate the LED and
gang the two channels of the unit together.
This has the effect of disabling the controls for channel B, as both channels
will assume the settings on channel A. Additionally, the sidechains will be
linked so that, if one channel opens so will the other, so avoiding any shifts
in the stereo image.
Metering remains independent between the two channels. Note that as soon as the
stereo linking is turned off, channel B will assume the parameters as set by its
controls. This might have a dramatic effect on the level of the channel, so be careful!