XTA E2 Operator'S Manual Download Page 4

Page 4   

 

 

 

 

 

 

             

E2

 Operators Manual 

 

 

 

An example of this equipment has been tested and found to comply with 

the following European and international Standards for Electromagnetic 
Compatibility and Electrical Safety: 

 

Radiated Emissions (EU): 

EN55013-1 (1996)  

RF Immunity (EU): 

EN55103-2 (1996) RF Immunity, ESD, Burst Transient, 
Surge, Dips &Dwells   

Electrical Safety (EU):  

EN60065 (1993) 

 
 

 
 
Important Safety Information 

 

 

 

 

 

 

 
Do not remove Covers.  
No user serviceable parts inside, refer servicing to qualified service personnel. 
This equipment must be earthed. 
 

CAUTION 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN 

DO NOT EXPOSE TO RAIN OR MOISTURE 

 
 

ATTENTION 

RISQUE DE CHOC ELECTRIQUE 

NE PAS ENLEVER 

 NE PAS EXPOSER A LA PLUIE NI A L’HUMITE 

 
It should not be necessary to remove any protective earth or signal cable shield connections. 
Do not defeat the purpose of the polarized or grounding-type plug. A polarized plug has two 
blades with one wider than the other. A grounding type plug has two blades and a third 
grounding prong. The wider blade and the third prong are provided for your safety. When the 
provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete 
outlet. 
Only use this equipment with an appropriate mains cord. 
In the USA the cord should comply with the requirements contained in the Standard for Cord 
Sets and Power Supply Cords, UL 817, be marked VW-1, and have an ampacity rating not less 
than the marked rating of the apparatus.

 

 

Summary of Contents for E2

Page 1: ......

Page 2: ...ers show level just before the DAC and will be affected by the output gain control Input and output gain is not bypassed when the Master switch is off High and low pass filters are bypassed my the Mas...

Page 3: ...the E2 5 Introduction 6 Features 6 Front Panel Familiarisation 7 Rear Panel Connections 9 Operating the E2 10 Switching the unit on and start up procedure 10 Minimum and maximum control positions 10 O...

Page 4: ...E CHOC ELECTRIQUE NE PAS ENLEVER NE PAS EXPOSER A LA PLUIE NI A L HUMITE It should not be necessary to remove any protective earth or signal cable shield connections Do not defeat the purpose of the p...

Page 5: ...d and engineered for cutting edge performance and world class reliability If you would like further information about this or any other XTA product please contact us We look forward to hearing from yo...

Page 6: ...t internal processing and a professional 48kHz sampling rate The E2 is also available with optional AES EBU digital inputs and outputs Features Four bands of full range equalisation on each channel In...

Page 7: ...l Adjust the amout of cut or obbst of the selected band of frequencies Note the asymmetric nature of the control 25dB of cut is available and 15dB of boost Frequency Control In conjunction with the ra...

Page 8: ...rder response 12dB per Octave roll off or a steeper 4th order response 24dB per Octave Output Gain Control To compensate for large amounts of cut or boost and bring the output level back to that at th...

Page 9: ...proof holder adjacent to the mains inlet A spare fuse is also located in this holder Mains Inlet connected via a standard IEC socket Audio In Out 3 pin XLR sockets are provided for each channel All ar...

Page 10: ...illuminated and after the bypass relays disengage a pattern will undulate across the LEDs as the level fades up The entire process is complete when the input output meters begin to operate normally T...

Page 11: ...that option not a safe operating level Always ensure that this clipping point is no lower than that for the following equipment in the signal chain and allow extra margin if equalisation sections are...

Page 12: ...igh shelf bands 1 4 resp or parametric response Centre corner Freq 20Hz to 20k in three ranges Q 0 4 to 25 2 5 0 04 Octaves Gain 15dB to 25dB Input Output Gain Both 15 dB range Input meter 7 point 18d...

Page 13: ...service facility Defects caused by unauthorised modifications misuse negligence act of God or accident or any use of this product that is not in accordance with the instructions provided by XTA are no...

Reviews: