XTA E2 Operator'S Manual Download Page 2

Page 2   

 

 

 

 

 

 

             

E2

 Operators Manual 

 

E2

 Quick Reference 

 

 

 

 

THINGS YOU NEED TO KNOW… 

 

ü

 

The input meters show level, in dB, from 

the clipping point of the DSPs (digital 

signal processors) – the reading 

will

 be 

affected by the input gain control – it is 
post converter. 

 

ü

 

The output meters show level just before 
the DAC and 

will 

be affected by the 

output gain control. 

 

ü

 

Input and output gain is 

not

 bypassed 

when the Master switch is off. 

 

ü

 

High and low pass filters 

are

 bypassed my 

the Master switch. 

 

ü

 

The Listen LED always flashes when any 
Listen switch is enabled.  Listen is not 

automatically turned off if the unit is 

switched off and on 

 

ü

 

When the unit is bypassed, all its 
metering and status LEDs will dim.  All 

metering will continue to function. 

 

 
 

Summary of Contents for E2

Page 1: ......

Page 2: ...ers show level just before the DAC and will be affected by the output gain control Input and output gain is not bypassed when the Master switch is off High and low pass filters are bypassed my the Mas...

Page 3: ...the E2 5 Introduction 6 Features 6 Front Panel Familiarisation 7 Rear Panel Connections 9 Operating the E2 10 Switching the unit on and start up procedure 10 Minimum and maximum control positions 10 O...

Page 4: ...E CHOC ELECTRIQUE NE PAS ENLEVER NE PAS EXPOSER A LA PLUIE NI A L HUMITE It should not be necessary to remove any protective earth or signal cable shield connections Do not defeat the purpose of the p...

Page 5: ...d and engineered for cutting edge performance and world class reliability If you would like further information about this or any other XTA product please contact us We look forward to hearing from yo...

Page 6: ...t internal processing and a professional 48kHz sampling rate The E2 is also available with optional AES EBU digital inputs and outputs Features Four bands of full range equalisation on each channel In...

Page 7: ...l Adjust the amout of cut or obbst of the selected band of frequencies Note the asymmetric nature of the control 25dB of cut is available and 15dB of boost Frequency Control In conjunction with the ra...

Page 8: ...rder response 12dB per Octave roll off or a steeper 4th order response 24dB per Octave Output Gain Control To compensate for large amounts of cut or boost and bring the output level back to that at th...

Page 9: ...proof holder adjacent to the mains inlet A spare fuse is also located in this holder Mains Inlet connected via a standard IEC socket Audio In Out 3 pin XLR sockets are provided for each channel All ar...

Page 10: ...illuminated and after the bypass relays disengage a pattern will undulate across the LEDs as the level fades up The entire process is complete when the input output meters begin to operate normally T...

Page 11: ...that option not a safe operating level Always ensure that this clipping point is no lower than that for the following equipment in the signal chain and allow extra margin if equalisation sections are...

Page 12: ...igh shelf bands 1 4 resp or parametric response Centre corner Freq 20Hz to 20k in three ranges Q 0 4 to 25 2 5 0 04 Octaves Gain 15dB to 25dB Input Output Gain Both 15 dB range Input meter 7 point 18d...

Page 13: ...service facility Defects caused by unauthorised modifications misuse negligence act of God or accident or any use of this product that is not in accordance with the instructions provided by XTA are no...