Each output features variable high and low pass filters, with a choice of 12, 18
or 24dB/Octave roll-off, and Butterworth, Bessel or Linkwitz-Riley responses.
Independent control of each high and low pass filter allows asymmetric
crossover bands to be created.
♦
Delay of up to 650mS may be independently set for each output, with an
exceptionally fine minimum increment of 2.6µS.
♦
The comprehensive standard specification also includes 40 memories, and
remote control via MIDI, RS232 or RS485 ports, with security lock-out.
♦
AES/EBU Digital input and output interfaces are available as an option.
♦
Input and output balancing transformers are also available as an option.
♦
A general purpose interface (GPI) is available as a option, allowing simple
remote memory recall without the need to connect a PC.