background image

Rear Panel Functions

1.

Mains Power

 - is connected via a standard IEC socket.  A compatible power cord is

supplied with the unit.

2.

Mains Fuse

 - is located in a finger-proof fuseholder adjacent to the mains inlet.  Always

replace this fuse with the correct type as shown on the rear panel legend.

3.

Power Switch

 - a double pole rocker switch isolates both live and neutral connections.

4.

MIDI 

- In / Thru and Out connections are provided via standard 5 pin DIN sockets. See

page 15 for more information.

5.

XLR Inputs and Outputs

 - Separate 3 pin XLR connectors are provided for each audio

input and output.  All terminations are fully balanced where pin 2 = Hot, pin 3= Cold and
pin 1 = Screen (shield).  See page 17 for more information.

6.

Digital Output 3+4 Switch

 - pressing this recessed switch will route the AES digital

format of outputs 3 and 4 via output 3's XLR connector, if the AES/EBU option is fitted.

7.

Digital Output 1+2 Switch

 - pressing this recessed switch will route the AES digital

format of outputs 1 and 2 via output 1's XLR connector, if the AES/EBU option is fitted.

8.

Digital Input Switch

 - pressing this recessed switch will change XLR Input A to a 2

channel AES digital format input, if the AES/EBU option is fitted.

DP100 Page 4

Summary of Contents for DP100

Page 1: ......

Page 2: ...Functions 4 DP100 Block Diagrams 5 Operating The DP100 6 Preliminary Setup 7 Basic Delay Mode 8 Output Equalisation Mode 9 DP100 Equalisation Curves 10 Memory Store 11 Memory Recall 12 Delay Measurem...

Page 3: ...g mains power This voltage is confirmed on the voltage label affixed to the rear of the unit The voltage selector switch is located inside the DP100 Refer adjustment to qualified personnel Do not expo...

Page 4: ...e standard specification includes 80 memories MIDI for external control linking master slave units selectable operating level and security lock out function Delay measurement mode simplifies set up by...

Page 5: ...In Output EQ mode the Delay key selects between the three EQ parameters Gain Frequency and Q 6 Gain Key Allows gain to be adjusted via the parameter control for the output currently shown in the LCD...

Page 6: ...uts Separate 3 pin XLR connectors are provided for each audio input and output All terminations are fully balanced where pin 2 Hot pin 3 Cold and pin 1 Screen shield See page 17 for more information 6...

Page 7: ...2 DELAY 3 BAND EQ GAIN D A OP LEV BAL OUT 3 DELAY 3 BAND EQ GAIN D A OP LEV BAL OUT 4 BAL IN B OP LEV METER A D B A S E D E L A Y Dual Configuration DELAY 3 BAND EQ GAIN D A OP LEV BAL OUT 1 BAL IN A...

Page 8: ...type See page 11 for more information Memory Recall Allows recall of all currently used memories as selected via the parameter control See page 12 for more information Security System Allows a securit...

Page 9: ...more information Preliminary Setup The following procedure should be followed when first installing the DP100 1 Select correct unit configuration via menu 2 Set maximum input level operating level vi...

Page 10: ...y shown in the LCD display Gain is variable between 0dB and 40dB of attenuation plus mute This function also cancels after 15 seconds 8 Scroll Key scrolls to the next output for previewing on the LCD...

Page 11: ...ut No shows the output currently selected for adjustment 2 Section No shows the parametric section currently selected 3 per output 3 Frequency displays centre frequency for the filter section currentl...

Page 12: ...symmetrical boost cut response of a single section at various gains Figure 2 shows the range of filter Q s available Figure 3 shows filter sections set at 30Hz and 18kHz and low Q to produce shelving...

Page 13: ...t required memory 4 Enter key Pressing this key stores all current parameters into the chosen memory Previously used memories identified by a after Mem No must be over written by pressing ENTER again...

Page 14: ...shown on the DP100 s LCD display This system replaces the use of a tape measure or the trial and error approach allowing the required delay time to be determined quickly for each loudspeaker zone and...

Page 15: ...adjustment of output level for selected output 4 Scroll key Allows the required output to be selected Once the measurement function has been initiated pressing this key toggles the tone burst frequen...

Page 16: ...999 can be chosen via the parameter control 3 Parameter Control Allows the required security code number to be selected This number must be written down and saved for future use 4 Enter key Once the r...

Page 17: ...en a memory is recalled The program change number is the same as the DP100 memory number being recalled i e 1 to 20 therefore if a Master DP100 is used to control a number of Slave DP100 units the cor...

Page 18: ...2dB steps Centre frequency 20Hz 20kHz 1 24 octave steps Filter Q 0 5 to 32 Operating level Headroom selectable 3dB 8dB 15dB 20dB Temp Correction 0 C to 40 C in 1 steps Display 2 x 20 character backli...

Page 19: ...g point for that option not a safe operating level Always ensure that this clipping point is no lower than that for the following equipment in the signal chain and allow extra margin if equalisation s...

Page 20: ...to be defective provided that the product is returned shipping prepaid to an authorised XTA service facility Defects caused by unauthorised modifications misuse negligence act of God or accident or an...