background image

Thanks

Thank you for choosing the XTA DP100 for your application.  Please spare a little time to

digest the contents of this manual (figuratively speaking), so that you obtain the best

possible performance from this unit.

All XTA products are carefully engineered for world class performance and reliability.

If you would like further information on this or any other XTA product, please call us.

We look forward to helping in the near future.

XTA Electronics Ltd.

Safety Warnings

Please note the following information which is provided for your safety:

Check correct operating voltage is set on the power supply before connecting mains
power. This voltage is confirmed on the voltage label affixed to the rear of the unit. The
voltage selector switch is located inside the DP100 - Refer adjustment to qualified
personnel.

Do not expose this unit to rain or moisture.

Do not expose this unit to excessive heat.

Replace all fuses with correct type only.

Do not remove the covers from this unit. No user serviceable parts inside - refer all
servicing to qualified personnel.

The mains power cord is fitted with a safety earth (ground) connection.  Do not operate this

unit with this connection removed.

Unpacking the DP100

After unpacking the unit please check carefully for damage.  If damage is found, please

notify the carrier concerned at once.  Any claim must be instigated by you, the consignee.

Please retain all packaging in case of future reshipment.

DP100 Page 1

Summary of Contents for DP100

Page 1: ......

Page 2: ...Functions 4 DP100 Block Diagrams 5 Operating The DP100 6 Preliminary Setup 7 Basic Delay Mode 8 Output Equalisation Mode 9 DP100 Equalisation Curves 10 Memory Store 11 Memory Recall 12 Delay Measurem...

Page 3: ...g mains power This voltage is confirmed on the voltage label affixed to the rear of the unit The voltage selector switch is located inside the DP100 Refer adjustment to qualified personnel Do not expo...

Page 4: ...e standard specification includes 80 memories MIDI for external control linking master slave units selectable operating level and security lock out function Delay measurement mode simplifies set up by...

Page 5: ...In Output EQ mode the Delay key selects between the three EQ parameters Gain Frequency and Q 6 Gain Key Allows gain to be adjusted via the parameter control for the output currently shown in the LCD...

Page 6: ...uts Separate 3 pin XLR connectors are provided for each audio input and output All terminations are fully balanced where pin 2 Hot pin 3 Cold and pin 1 Screen shield See page 17 for more information 6...

Page 7: ...2 DELAY 3 BAND EQ GAIN D A OP LEV BAL OUT 3 DELAY 3 BAND EQ GAIN D A OP LEV BAL OUT 4 BAL IN B OP LEV METER A D B A S E D E L A Y Dual Configuration DELAY 3 BAND EQ GAIN D A OP LEV BAL OUT 1 BAL IN A...

Page 8: ...type See page 11 for more information Memory Recall Allows recall of all currently used memories as selected via the parameter control See page 12 for more information Security System Allows a securit...

Page 9: ...more information Preliminary Setup The following procedure should be followed when first installing the DP100 1 Select correct unit configuration via menu 2 Set maximum input level operating level vi...

Page 10: ...y shown in the LCD display Gain is variable between 0dB and 40dB of attenuation plus mute This function also cancels after 15 seconds 8 Scroll Key scrolls to the next output for previewing on the LCD...

Page 11: ...ut No shows the output currently selected for adjustment 2 Section No shows the parametric section currently selected 3 per output 3 Frequency displays centre frequency for the filter section currentl...

Page 12: ...symmetrical boost cut response of a single section at various gains Figure 2 shows the range of filter Q s available Figure 3 shows filter sections set at 30Hz and 18kHz and low Q to produce shelving...

Page 13: ...t required memory 4 Enter key Pressing this key stores all current parameters into the chosen memory Previously used memories identified by a after Mem No must be over written by pressing ENTER again...

Page 14: ...shown on the DP100 s LCD display This system replaces the use of a tape measure or the trial and error approach allowing the required delay time to be determined quickly for each loudspeaker zone and...

Page 15: ...adjustment of output level for selected output 4 Scroll key Allows the required output to be selected Once the measurement function has been initiated pressing this key toggles the tone burst frequen...

Page 16: ...999 can be chosen via the parameter control 3 Parameter Control Allows the required security code number to be selected This number must be written down and saved for future use 4 Enter key Once the r...

Page 17: ...en a memory is recalled The program change number is the same as the DP100 memory number being recalled i e 1 to 20 therefore if a Master DP100 is used to control a number of Slave DP100 units the cor...

Page 18: ...2dB steps Centre frequency 20Hz 20kHz 1 24 octave steps Filter Q 0 5 to 32 Operating level Headroom selectable 3dB 8dB 15dB 20dB Temp Correction 0 C to 40 C in 1 steps Display 2 x 20 character backli...

Page 19: ...g point for that option not a safe operating level Always ensure that this clipping point is no lower than that for the following equipment in the signal chain and allow extra margin if equalisation s...

Page 20: ...to be defective provided that the product is returned shipping prepaid to an authorised XTA service facility Defects caused by unauthorised modifications misuse negligence act of God or accident or an...

Reviews: