33
troubleshooting
SYMPTOM
PROBABLE CAUSE
REMEDY
Detergent will not
siphon .
Detergent strainer is not
completely submerged in
detergent solution.
Check, submerge if necessary.
Detergent strainer
obstructed.
Inspect, clean or replace.
Detergent hose cut,
obstructed or kinked.
Inspect, clean or replace.
Detergent adjusting knob
turned to closed position.
Open adjusting knob. Refer to
“Cleaning with Detergents”.
Water flows back into
detergent container.
Ball & Spring in detergent
strainer
is obstructed.
Remove, clean or replace.
Water flows from the
nozzle when the trigger
gun is locked in the
“OFF” position
Trigger gun is
malfunctioning.
Repair or replace.
Blower motor will not
run. (Burner will not
ignite without blower
running)
Generator malfunction.
Repair or replace.
Burner/Blower motor
malfunction.
Repair or replace.
Belt broken or slipping on
generator.
Adjust or replace as necessary.
Blower runs, but
burner will not ignite.
Burner switch is not turned
on.
Check switch position.
Thermostat knob is OFF.
Check thermostat knob position.
Trigger gun is closed.
Open gun for pressure.
Out of fuel.
Refuel.
Detergent valve is open, but
detergent hose is not
completely submerged
in solution. (This causes
safety devices to shut down
burner.)
Close valve, or completely
submerge clear vinyl hose into
detergent solution.
Pressure switch override.
Pressure should be over 375
PSI to allow burner to come on.
No voltage.
Consult Service Department.
Poor or improper fuel
supply.
Check fuel to ensure it is
correct. Drain tank and filter if
necessary and refill with proper
fuel.
Fuel pump sucking air.
Tighten all fuel intake
connections. Eliminate leaks in
intake line.