27
maintenance
CLEANING THE AIR FILTER
A dirty air filter will reduce the compressor’s performance and life. To
avoid any internal contamination of the pump, the filter should be cleaned
frequently, and replaced on a regular basis. Felt filters should be cleaned
in warm, soapy water, rinsed, and allowed to air dry before reinstalla-
tion. Paper filters should be replaced when dirty. Do not allow the filter
to become filled with dirt or paint. If the filter becomes filled with paint, it
should be replaced. Direct exposure to dirty conditions or painting areas
will void your warranty.
CHECkING THE RELIEF VALVE
Pull the relief valve daily to ensure that it is operating properly and to clear
the valve of any possible obstructions.
TESTING FOR LEAkS
Check that all connections are tight. A small leak in any of the hoses,
transfer tubes, or pipe connections will substantially reduce the perfor-
mance of your air compressor. If you suspect a leak, spray a small amount
of soapy water around the area of the suspected leak with a spray bottle.
If bubbles appear, repair or replace the faulty component. Do not over-
tighten any connections.
STORAGE
Before storing the compressor for a prolonged period, use an air blow
gun to clean all dust and debris from the compressor. Disconnect the
power cord and coil it up. Pull the pressure relief valve to release all
pressure from the tank. Drain all moisture from the tank. Clean the filter
element and filter housing; replace the element if necessary. Drain the
oil from the pump crankcase and replace it with new oil. Cover the entire
unit to protect it from moisture and dust.