safety
CAUTION
1.
Drain the moisture from the tank on a daily basis. A clean, dry tank
will help prevent corrosion.
2.
Pull the pressure relief valve ring daily to ensure that the valve
is functioning properly, and to clear the valve of any possible
obstructions.
3.
To provide proper ventilation for cooling, the compressor must be
kept a minimum of 12 inches (31 cm) from the nearest wall, in a
well-ventilated area.
4.
To prevent damage to tank and compressor on stationary models,
the tank must be shimmed to the pump base is level within 1/8” to
distribute oil properly. All feet must be supported, shimming where
necessary, prior to attaching to the floor. Fasten all feet to floor. We
also recommend the use of vibration pads (094-0137) under tank
feet.
5.
Fasten the compressor down securely if transporting is necessary.
Pressure must be released from the tank before transporting.
6.
Protect the air hose from damage and puncture. Inspect them
weekly for weak or worn spots, and replace if necessary.
7.
To reduce the risk of electric shock, do not expose to rain. Store
indoors.