Rev1
Page 8 of 14
Screen capture of the Initial set up
using the Linear method
2
nd
half of the Linear method
The spacing is even between the
cable pull settings. The range is
based on the number of gears and
the limits that were entered in step
2.
Screen capture of the initial set up
using the Natural method
2
nd
half of the Natural method
The cable spacing is based on the
outer diameter sizes of the gears.
This setting tries to accommodate
for the increasing sizes of the
rings.
The range is based on the number
of gears and the limits that were
entered in step 2.
Step 4 Calibration
After you have set each ring and
you are able to crank and shift the
gears in step 3 you need to
calibrate the ELink.
Simply click on the calibrate button
to lock in the settings.
Be sure to be spinning the crank
while doing this function as the
derailleur will move to the smallest
ring.
The App will gray out and go back
to a ready state after the function
is finished.