Document MT0605P.E
© Xsens Technologies B.V.
MTi User Manual
36
4.6.2
Accelerometers and magnetometer
The MTi 10-series and MTi 100-series use the same accelerometers and magnetometer. The output
of the magnetometer is in arbitrary units (a.u.), one a.u. is the magnetic field strength during calibration
at Xsens
’ calibration lab. This is approximately 40 uT. An accelerometer range of 15g is available as
well.
Accelerometers/magnetometer: all products: MTi-10, MTi-20, MTi-30, MTi-100, MTi-200, MTi-300,
MTi-G-700
Accelerometers/magnetometers specification
MTi 10-series and
MTi 100-series
Acceleration
Typical
Max
Standard full range
[m/s2]
50
-
Bias repeatability (1 yr)
[m/s2]
0.03
0.05
In-run bias stability
[µg]
40
-
Bandwidth (-3dB)
[Hz]
375
N/A
Noise density
[µg/√Hz]
80
150
Non-orthogonality
[deg]
0.05
0.05
Non-linearity
[% FS]
0.03
0.5
A/D resolution
[bits]
16
N/A
Magnetic field
Full range
[µT]
-
80
Noise density
[µGauss/√Hz]
200
-
Non-linearity
[% FS]
0.1
-
A/D resolution
[bits]
12
N/A
4.6.3
Barometer
The barometer features barometric (atmospheric) pressure. The MTi-100 series feature this
barometer. The MTi 100-series has three holes with a protective vent in its casing in order to ensure
fast adaptation inside the MTi to atmospheric pressure. Typical latency because of the vent is <10 ms.
Barometer: MTi 100-series only: MTi-100, MTi-200, MTi-300, MTi-G-700
Barometer specification
Barometric pressure
N/A
Full range
[hpa]
-
300-1100
Noise density
[hpa
/√Hz]
0.01
-