background image

4

www.xprgroup.com

4.0 A

D

PPLICATION

IAGRAM

B100-SA

Standalone Biometric Reader

RTT

(Oponal)

1 Relay Remote Unit

and request-to-exit Bu on

Secur

ed Ar

ea

Outside

5.0 WIRING

NC

COM

NO

Tamp

Blue

Yellow

Red

Black

Pink

Violet

Orange

Gray

White

PB

R 485

S

+

_

12VDC

POWER SUPPLY

+

_

NC

COM

GND (PB)

PB

+

_

Electro Magnetic Lock

Green

Blue

Yellow

Red

Black

Pink

Violet

Orange

Gray

White

Green

Relay

(2A)

Push Button

1N4001

Diode

12V DC

GND
A
B

R 485 (max. 50m)

S

Wiring B100-SA + RTT (Remote Relay Unit)

Wiring B100-SA

12 VDC

+

-

1N4007

+

-

RTT

Black

Red

Pink

Violet

Black

Brown

Pink

Violet

Red

White

Yellow

COM

NO

GND

12V out

A

(RS485)

B

(RS485)

B100-SA

Pink
Violet
Brown

Red
Black
White
Yellow
Gray

Green

Orange

Blue

+12V

GND
NO
COM

A

B

NC

P 1

B

TAMP

TAMP

RS 485

Relay

(2A)

+12V Out

Power Supply

B100-SA

Standalone Biometric Reader

RTT

1 Relay Remote Unit

and request-to-exit Bu on

Relay1 time

(for Relay 1 in B100-SA, RTT and DINRTT )

Swipe the Master/Admin

finger

8 times

Select relay open time

1 sec

3 sec

5 sec

10 sec

20 sec

30 sec

60 sec

Toggle

Scroll down to select:

OK Beep

Back to MAIN MENU

Blinking row >

BL

BL

BL

BL

BL

BL

BL

BL

Relay2 time

(for Relay 2 in DINRTT Remote Relay Unit)

Select relay open time

1 sec

3 sec

5 sec

10 sec

20 sec

30 sec

60 sec

Toggle

Scroll down to select:

OK Beep

Back to MAIN MENU

Blinking row >

BL

BL

BL

BL

BL

BL

BL

BL

11.8 Set Door Relay Time

11.0 B100-SA P

M

ROGRAMMING

ENU

17

www.xprgroup.com

Swipe the Master/Admin

finger

9 mes

Tap sensor

Tap sensor

x 9

x 8

Tap sensor

Tap sensor

NOTE:
Swipe UPWARDS
to exit the MENU

Example:
Task: Put Relay1 to stay acvated 10 seconds.

Scroll Master Finger 8 mes, tap, scroll 3 mes, tap, swipe UP to exit.

Summary of Contents for RTT

Page 1: ...n addition it complies with RoHS directive EN50581 2012 Visual Plus Corporation s a Dr ve Richelle 161 WOP G Bte 34 1410 Waterloo Belgium www xprgroup com User Manual v a3 EN B100 SA KIT Standalone Bi...

Page 2: ...7 7 7 8 8 8 8 9 9 10 10 11 12 13 14 15 16 17 Contents B100 SA is a simple one door standalone biometric system The reader can store up to 97 finger templates it has one relay output and one exit butt...

Page 3: ...before are not followed It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use different readers dep...

Page 4: ...TAMP TAMP RS 485 Relay 2A 12V Out Power Supply B100 SA Standalone Biometric Reader RTT 1 Relay Remote Unit and request to exit Bu on Relay1 time for Relay 1 in B100 SA RTT and DINRTT Swipe the Master...

Page 5: ...e first finger joint place the selected finger on the swipe sensorandmoveitevenlytowardsoneselfinonesteadymovement Result For a valid swipe Tricolour Status LED turns green OK Beep short long beep For...

Page 6: ...ramming feature the Users are assigned in Group 1 or Group 2 For most of the installa ons 2 groups are enough and can be used as Group 1 for permanent residents Group 2 for guest and visitors 4 The us...

Page 7: ...s 2 Wait for the light pa ern on gure 4 6 seconds 3 Swipe the Master or Admin nger once more Figure 1 Figure 2 6 sec 6 sec 7 www xprgroup com 1 Swipe the Master or Admin Finger 2 Swipe the user nger m...

Page 8: ...devices or refer to the Remote Relay s Manual 10 0 K D U EEP THE OOR NLOCKED User Finger x 2 Swipe ANY enrolled nger twice within 7 seconds and the Door will stay unlocked un l valid nger is swiped Wh...

Page 9: ...e Administrator but the Administrator can not delete the Master NOTE Swipe UPWARDS to exit the MENU Tap sensor Tap sensor Select User Group Orange Blinking Group 1 Group 2 Group 3 Group 4 Group 5 Grou...

Page 10: ...e deleted NOTE Swipe UPWARDS to exit the MENU NOTE Swipe UPWARDS to exit the MENU Tap sensor Tap sensor Select User Group to Delete Swipe the finger to select OK Beep Group 1 Group 2 Group 3 Group 4 G...

Reviews: