background image

DINRTT

(Optional)

2 Relay Remote Unit

and request-to-exit Button

B100PROX-MF-SA

Standalone Biometric Reader

OR

RTT

(Optional)

1 Relay Remote Unit

and request-to-exit Button

Secur

ed

Ar

ea

Outside

R 485 (max. 50m)

S

Fingerprint Capacity:
Prox. cards Capacity:
Card Type:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Master/Admin Fingers:
Image resolution:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
Mounting:
IP Factor:
Storage/Operating Temperature:
Storage/Operating Humidity:
Dimensions(mm):

97 templates
97 cards

Mifare (13,56 Mhz,  Mifare Classic 1K & 4K, Ultralight, Desfire)

1 x Relay (2A/24V AC/DC)
Yes
Pulse (1, 3, 5, 10, 20, 30, 60sec) or Toggle(ON/OFF)
Finger; Finger or/and Card; Finger on Card;
By scrolling and tapping on the sensor
1 Master and 2 Admin Fingers
Up to 508 DPI
Yes
Yes
via

converter and windows application

R 485

S

150 mA max.
9-14 V DC
Tricolor Status LED and 4 x Programming LEDs
Flush mount
IP65
-20°C to +50°C
5% to 93% RH without condensation
100 x 94 x 30

N 1

O

COM N 1

C

N 1

O

COM N 1

C

R 2

U

(Optional)

2 Relay Remote Unit

4

3.0 SPECIFICATIONS

4.0 A

D

PPLICATION

IAGRAM

Continues on the

next 2 pages

Blinking row >

Swipe the Master/Admin finger

unl

10 mes

the light pa ern on figure.7 is shown

Figure.7

x 10

Tap sensor

Tap sensor

Entry Mode

- used when addional proximity or keypad reader is connected

Remote Relay Touch Funcon

- Enabling/Disabling the Touch Bu on Funcon in the remote relay Unit

Buzzer

- Enabling/Disabling the Buzzer

Backlight

- Enabling/Disabling the Backlight

go to next page

NOTE:
Swipe UPWARDS
to exit the MENU

Double Swipe Unlocks Door

Sensor security

Entry mode

Remote Relay
Touch Function

Buzzer

Backlight

Reset to defaults

Swipe the finger to select:

BL

BL

BL

BL

BL

BL

BL

By swiping finger select appropriate light pa ern

17

11.0 B100PROX-MF-SA P

M

ROGRAMMING

ENU

11.8 Settings

Summary of Contents for B100PROX-MF-SA

Page 1: ...MENU Blinking row BL BL BL BL BL BL BL BL Swipe the Master Admin nger 9 mes Tap sensor Tap sensor x 9 x 8 Tap sensor Tap sensor NOTE Swipe UPWARDS to exit the MENU Example Task Put Relay1 to stay ac...

Page 2: ...dd Administrator 11 7 Delete Administrator 11 8 Settings 11 8 1 Double Swipe Unlocks Door Entry Mode Remote Relay Touch Function 11 8 2 Buzzer Sound Backlight Reset to defaults 11 9 Set Door Relay Tim...

Page 3: ...ace of the TouchChip sensor provides protection from scratching and abrasion due to normal contact with fingertips and any incidental contact with fingernails The reader is capable of working in so ca...

Page 4: ...ia converter and windows application R 485 S 150 mA max 9 14 V DC Tricolor Status LED and 4 x Programming LEDs Flush mount IP65 20 C to 50 C 5 to 93 RH without condensation 100 x 94 x 30 N 1 O COM N 1...

Page 5: ...amp Blue Yellow Red Black Pink Violet Orange Gray White PB R 485 S _ 12VDC POWER SUPPLY _ NC COM GND PB PB _ Electro Magnetic Lock Green Blue Yellow Red Black Pink Violet Orange Gray White Green Colou...

Page 6: ...sensor UP to exit the programming menu Navigate the Programming Menu Exit the Programming Menu 6 6 0 R S T ECOMMENDED WIPING ECHNIQUE 6 1 Taping the sensor 6 2 Scrolling the sensor up and down 7 0 IN...

Page 7: ...r Groups With the Quick programming feature the Users are assigned in Group 1 or Group 2 For most of the installations 2 groups are enough and can be used as Group 1 for permanent residents Group 2 fo...

Page 8: ...When using proximity reader for Finger Or And Card Mode first present the Card then swipe the finger min 6 times With this the quick programming is completed The system is now operational with default...

Page 9: ...the Reader in Finger ON Card mode Follow the procedure on page 16 17 1 Swipe the Master or Admin Finger twice 2 Swipe the user finger min 6 times until Ok Beep 3 Present the Card and hold it in the p...

Page 10: ...stand activation in longer periods 12 VDC 1N4007 RTT Black Red Pink Violet Black Brown Pink Violet Red White Yellow COM NO GND 12V out A RS485 B RS485 B100PROX MF SA Black Red Pink Violet B R 48 5 S 1...

Reviews: