xpr B100PROX-EH-SA v2 Installer Manual Download Page 4

Fingerprint Capacity:
Prox. cards Capacity: 
Card Type:
 
Output:        
Push Button Input:   
Door Open Time:          
Entry Mode:
Programming:
Master/Admin Fingers:        
Backlight ON/OFF: 
Buzzer ON/OFF:
Firmware upgrade:         
Current Consumption:
Power Supply: 
Indication:                                          
IP Factor:
Storage/Operating Temperature  :
Storage/Operating Humidity:
Dimensions(mm):   

98 templates
2000 cards
EM or HID compatible (125KHz) - 

B100PROX-EH-SA

 

or Mifare (13,56 Mhz; Classic 1K & 4K, Ultralight, Desfire)

 

B100PROX-MF-SA

1 x Relay (2A/24V AC/DC)
Yes
Pulse (1 to 30 seconds) or Toggle(ON/OFF)
Finger or Card
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes
via 

 converter and windows application

RS485

150 mA max.
9-14 V DC
Tricolor Status LED
IP65
-20°C to +50°C
5% to 93% RH without condensation 
100 x 94 x 30

4

SPECIFICATIONS

APPLICATION DIAGRAM

RS

485 (ma

x. 50m)

DINRTT

 

(Op onal)

2 Relay Remote Unit

and request-to-exit Bu on

RTT

 

(Op onal)

1 Relay Remote Unit

and request-to-exit Bu on

RU2

 

(Op onal)

2 Relay Remote Unit

OR

Secured Area

Outside

B100PROX-EH/MF-SA v2

Standalone Biometric Reader

MCD-MINI

 

(Op onal)

Metal Cover

Summary of Contents for B100PROX-EH-SA v2

Page 1: ...B100PROX EH SA v2 B100PROX MF SA v2 Standalone Biometric Reader 1 INSTALLER S MANUAL v c2...

Page 2: ...is access control ngerprint reader designed for easy management of the users and con guration The scanner is made with advanced capacitive sensing technology that provides some advantages over optical...

Page 3: ...tly the dirt Do not use chemicals and materials that can scratch the sensor WARNING 3 MOUNTING 100 mm 94 mm 30 mm Cable 6 0 30mm MCD MINI Do not install the device and cabling close to a source of str...

Page 4: ...ht Desfire B100PROX MF SA 1 x Relay 2A 24V AC DC Yes Pulse 1 to 30 seconds or Toggle ON OFF Finger or Card By swiping 1 Administrator and 1 Installer Finger Yes Yes via converter and windows applicati...

Page 5: ...ND PB PB _ Blue Yellow Red Black Pink Violet Orange Gray White Green 1N4001 Diode Electric Strike ON 1 2 ON 1 2 Adding Admin Finger CARD Type Dipswitch A Card Type ON HID OFF EM ON 1 2 Dipswitch A Dip...

Page 6: ...nected relay unit RTT DINRTT or RU2 x6 ON 1 2 ON 1 2 Tricolor Status LED Access Granted Green Access denied Red Idle Mode Orange OK Beep short long beep 3 short beeps Error Beep Swipe Finger 2 short b...

Page 7: ...connected to remote relay unit at secured area which also can play the role of request to exitpushbutton Followtheinstructionsbellowtopair couple bothdevicesorrefertotheRemoteRelay sManual 12 VDC 1N4...

Page 8: ...t Buzzer Sound x 2 ADD Finger Relay 2 Finger that will activate remote relay 2 slow blinking fast blinking short beep short long beep short beep Swipe User Finger min 6 times until short long beep x 6...

Page 9: ...5 x 6 short beep short long beep 3 short beeps Swipe Admin Finger 6 times Action Wait 5 seconds until fast blinking Swipe NEW Installer Finger min 6 times Finger Backlight Buzzer Sound x 6 x 6 CHANGE...

Page 10: ...ent card tag SWIPE new finger min 6 times or present card tag SWIPE ADMIN finger 2 times to DELETE ALL SWIPE new ADMIN FINGER min 6 times SWIPE new INSTALLER FINGER min 6 times Swipe the ADMIN Finger...

Page 11: ...Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode fast blinking short long beep x 1 x 1 Swipe Installer Finger 3 times Action Swipe Installer Finger Finger Backligh...

Page 12: ...OFF Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle ON OFF mode Only in combination with DINRTT and RU2 Swipe the Installer Finger and start counting seconds Swipe the...

Reviews: