![xpr B100P-BT-EH-SA User Manual Download Page 2](http://html1.mh-extra.com/html/xpr/b100p-bt-eh-sa/b100p-bt-eh-sa_user-manual_3610251002.webp)
2
4. WIRING AND PAIRING
The Bluetooth reader must be connected to
remote relay unit, unless is used as wiegand
reader.
The remote relay units compatible with B100P-BT-
EH-SA are RU1, RU2, RTT and DINRTT. Once
connected, the remote relay unit must be paired
with the Bluetooth reader.
Pairing the reader with remote relay unit is done
from the remote relay unit and enables added
security. After being paired, it is not possible to
switch any of the devices, since the reader will
work only with the paired remote relay unit.
Grey
Red
Black
White
Yellow
Pink
Blue
Violet
+12V
GND
D0
D1
RS-485
Power Supply
Wiegand
Tamper
A
B
to remote relay unit
to wiegand controller
IN
RS
-485 (max. 50m)
DINRTT
2 Relay Remote Unit
and request-to-exit Button
RTT
1 Relay Remote Unit
and request-to-exit Button
RU2
2 Relay Remote Unit
OR
Secured Area
Unsecured Area
+12V
GND
NO
COM
A
B
NC
PB
RS-485
Power
Supply
GND_PB
RU1
1 Relay Remote Unit
B100P-BT-EH-SA
Bluetooth standalone biometric reader
with integrated RFID reader
4.1 Wiring and pairing B100P-BT-EH-SA + RU1
+12V
GND
NO
COM
A
B
NC
PB
RS-485
Power
Supply
GND_PB
white
yellow
gray
red
black
blue
orange
violet
pink
Black
Red
Pink
Violet
Reader
Exit Button
12 VDC
+
-
+
-
max. 50 m
Pairing Reader with RU1 (high security)
- Keep the button pressed
for at least 5 sec. and the
units will be paired.
There are four options to wire and pair the reader. It can be paired to RU2, RU1, DINRTT and RTT.
4.2 Wiring B100P-BT-EH-SA to Wiegand Controller
Grey
Red
Black
White
Yellow
Pink
Blue
Violet
12V
DC(CC)
D0
D1
+
-
Host/ Unité Centrale/ Unita' centrale/
Sistema receptor/ Controller/ Controller
Max 150m
By default, the reader is set to Wiegand 26
bit.
You can set the reader, using the software,
to Wiegand 24, 26, 32, 34, 56, 58 bits.
Other pairing devices:
Device
Description
Relays
RU2
DINRTT
RTT
Flush mount sensitive push button and remote relay
DIN rail mount remote relay unit
Surface mount sensitive push button and remote relay
2
2
1