Connection example of 2 doors

This product herewith complies with requirements of EMC directive 2014/30/EU.

In addition it complies with RoHS2 directive EN50581:2012

Network

ON

1 2

OFF

(1)

(1)

(1)

V+

V-

+

-

Vi

n

Gnd

Gnd

Gnd

Gnd

Gnd

Gnd

Bat

G1+ Com N

O

N

C

D

C

Pb

LB

+

R- R+

M+

-

Gnd

G2

+

Com N

O

N

C

Com N

O

N

C

Com N

O

N

C

Com N

O

N

C

Gnd

D

C

2

Pb 

2

In 

1

In 

2

Gnd

5

5

7

7

6

6

Run Led

Box Tamper

Led Comm

Push button

Door contact

Net

Example:

emergency button

Reader

Reader

Door contact

Electromagnetic Lock 12V/600mA max

Power supply 14,2VDC

Push button

Address 0

Address 1

electric strike

12V/600mA max

See user manual

12V battery

Po

w

er f

or door lock

Gnd f

or DC and PB

Door Cont

act 2

Push Button 2

Gnd f

or inputs

Input 1

Input 2

Door R

ela

y 2

Po

w

er S

upply

Batter

y

Po

w

er f

or door lock

Door R

ela

y 1

GND f

or door lock

Door Cont

act 1

Push Button 1

Gnd f

or DC and PB

12 VDC f

or r

eader

RS45 -/R

S485 B

RS45 -/R

S485 A

Gnd f

or r

eader

Not used

Output 1

Output 2

Output 3

GND f

or door lock

1. The readers for Door 1.0 must be at address 0 and those for Door 1.1 at address 1.

2. For doors equipped with 2 readers, one must be at address 0 and the other at address 1.

3. The function of OUT1, OUT2 and OUT3 can be configured in the software

4. In1 & In2: Connect to GND by a volt-free contact to activate the input

5. LIYCY cable, twisted pair, up to 80m.

If more than 80 m. are needed, then termination resistors(120 ohm) may be required at both ends of 

the RS485 line,

while taking into consideration the lengths proposed on our web site.

6. Alarm cable 2x0,22

7. The cross section of the cable depends on the current needed by the lock

Note: 

The elevators relay boards (WS4-RB-12) are connected on the same RS485 lines as the readers.

OFF

ON

1

Lan

Autonomous

2

Master

Slave

Dip Switch