Connection example of 2 doors
This product herewith complies with requirements of EMC directive 2014/30/EU.
In addition it complies with RoHS2 directive EN50581:2012
Network
ON
1 2
OFF
(1)
(1)
(1)
V+
V-
+
-
Vi
n
Gnd
Gnd
Gnd
Gnd
Gnd
Gnd
Bat
G1+ Com N
O
N
C
D
C
Pb
LB
+
R- R+
M+
M
-
Gnd
G2
+
Com N
O
N
C
Com N
O
N
C
Com N
O
N
C
Com N
O
N
C
Gnd
D
C
2
Pb
2
In
1
In
2
Gnd
5
5
7
7
6
6
Run Led
Box Tamper
Led Comm
Push button
Door contact
Net
Example:
emergency button
Reader
Reader
Door contact
Electromagnetic Lock 12V/600mA max
Power supply 14,2VDC
Push button
Address 0
Address 1
electric strike
12V/600mA max
See user manual
12V battery
Po
w
er f
or door lock
Gnd f
or DC and PB
Door Cont
act 2
Push Button 2
Gnd f
or inputs
Input 1
Input 2
Door R
ela
y 2
Po
w
er S
upply
Batter
y
Po
w
er f
or door lock
Door R
ela
y 1
GND f
or door lock
Door Cont
act 1
Push Button 1
Gnd f
or DC and PB
12 VDC f
or r
eader
RS45 -/R
S485 B
RS45 -/R
S485 A
Gnd f
or r
eader
Not used
Output 1
Output 2
Output 3
GND f
or door lock
1. The readers for Door 1.0 must be at address 0 and those for Door 1.1 at address 1.
2. For doors equipped with 2 readers, one must be at address 0 and the other at address 1.
3. The function of OUT1, OUT2 and OUT3 can be configured in the software
4. In1 & In2: Connect to GND by a volt-free contact to activate the input
5. LIYCY cable, twisted pair, up to 80m.
If more than 80 m. are needed, then termination resistors(120 ohm) may be required at both ends of
the RS485 line,
while taking into consideration the lengths proposed on our web site.
6. Alarm cable 2x0,22
7. The cross section of the cable depends on the current needed by the lock
Note:
The elevators relay boards (WS4-RB-12) are connected on the same RS485 lines as the readers.
OFF
ON
1
Lan
Autonomous
2
Master
Slave
Dip Switch