PROGRAMMING FLOWCHART
Note:
Press B to exit the menu in
any stage of the programming.
EXAMPLES:
ADD PIN Code:
Assign User Code “12345” at Memory Position “5” and Relay 3 that activates for 4 seconds, assuming Master Code = 000.
Press 000B + 0 + 005 + 12345 + A + 3 + 005 + 3 + A + 2 + 04 + A + B.
Start
Enter “Master Code” OR “
000
”(if first time in use)
Validate by pressing (
B
)
1 small beep + 1 long beep + Yellow LED is ON
Validation
OK?
Multiple small beeps
+
Yellow LED blinks rapidly
NO
YES
ADD
User
Change
Master
Code
Set
Relay 1
Timer
Set
Relay 2
Timer
Assign
Output
Set
I/O board
Timer
Slave
Device
Buzzer
Backlight
Delete
All
Users
Delete
Single
User
Enter Memory
Position from
(
001
to
999
)
Enter new
Master
code
(1 to 8
digits)
Enter new code
(1 to 8 digits)
New User will
be assigned to
Relay1
Enter Memory
Position from
(
001
to
999
)
Press
A
to validate
Press
B
(Yellow LED is OFF)
END
Two Beeps
Multiple small beeps
+ Yellow LED blinks
rapidly
NO
YES
Validation
OK?
Press
999
Memory
position from
(
001
to
999
)
Press (from
01
to
99
)
for time in
seconds
If press
00
toggle mode
Default:
03
seconds
Press (from
01
to
99
)
for time in
seconds
If press
00
toggle
mode
Default:
03
seconds
Press (from
01
to
99
)
for time in
seconds
or press
00
toggle
mode
Default:
03
seconds
Press(
0
) for
Buzzer OFF
OR
Press(
1
) for
Buzzer ON
Press(
2
) for
Backlight OFF
OR
Press(
3
) for
Backlight ON
OR
Press(
4
) for
backlight on key
press
Press(
5
) for
dimmed
backlight
Press(
1
) for I/O
board (RB0408)
OR
Press(
2
) for
RTT/DINRTT/RU2
or none
Default:
RTT/DINRTT/RU2
Enter (
000
)
Press(
1
) for
Relay 1
OR/AND
Press(
3
) for
Relay3
OR/AND
Press(
4
) for
Relay 4
OR/AND
Press(
5
) for
Relay 5
OR/AND
Press(
6
) for
Relay 6
OR/AND
Press(
7
) for
Relay 7
OR/AND
Press(
8
) for
Relay 8
OR/AND
Press(
9
) for
Relay 9
OR/AND
Press(
0
) for
Relay 10