7. Methods for Malfunction
Malfunction 1
- The machine does not turn on.
(1) Check that the power supply is working, that there is good connection, and that the speed switch is
set to speed 1, 2, or 3 while the timer knob is pointing to ON or is greater than 0 (pointing to 0 is not
energized). If machine still does not turn on, proceed to method (2).
(2) Follow 3.1-3.5 to open the Air Mover. Check for loose terminal connections. (Fig. 21) Tighten if
necessary. If machine still does not turn on move on, proceed to method (3).
(3) Follow 4.1 to
disassemble.
Remove three wires
connected to Speed Switch. Use the Multimeter
(diode position, Fig. 24) to check conduction of Speed Switch at each speed level:
Adjust to speed 1, use the Multimeter to check the switch (Fig. 25);
Adjust to speed 2, use the Multimeter to check the switch (Fig. 26);
Adjust to speed 3, use the Multimeter to check the switch (Fig. 27);
If there is a speed that does not function properly, follow steps 4.1-4.3 to replace Speed Switch
Motor Medium Speed
Wire (Yellow)
Motor
Low
Speed
Wire (Brown)
Socket Lead Wire 1
(Red)
Motor High Speed
Wire (Black)
Motor Wire (White)
Socket Lead Wire 2
(Blue)
Power Line of N
(White)
Power Line of L (Black)
Socket Lead Wire 3
(Black)