English - 14
If troubleshooting does not resolve your problem, please contact XPOWER or other
parties authorized by XPOWER for further instructions.
Technical Specification
PROBLEM
POSSIBLE CAUSE
SOLUTION
Machine does not
start
Low battery capacity.
When the battery capacity
is 20% or lower, in order to
protect the battery, the preset
program will stop the machine
and prohibit the machine from
working again. (
See Page 6:
Charge the Battery.
)
Unit runs but the
speed or the sound
is abnormal
Air inlet or air outlet is blocked.
Remove blockage.
Low battery capacity.
When the battery capacity
is 20% or lower, in order to
protect the battery, the preset
program will stop the machine
and prohibit the machine from
working again. (
See Page 6:
Charge the Battery.
)
Misting function is
abnormal
The water hose is blocked.
Remove blockage.
The atomization assembly is
blocked.
Remove blockage. (
See Page
10: Atomization Assembly
Maintenance
)
The water switch is off or no
water supply.
Check for water supply.
Atomization Specification
Misting Nozzle
Max Mist Volume
Max Throw Distance
FM-65B
0.3 mm (Marked 3010)
5.9 L / h
29.5 ft. / 9.0 m
FM-65WB
/ FT-
65WB
0.3 mm (Marked 3010)
7.5 L / h
29.5 ft. / 9.0 m