XPOtool 63898 User Manual Download Page 9

 

https://www.XPOtool.com 

 

Item 63898

 

Page 9

 

The Tool Experts

 

 

  

 

12 2022-1

 

 

 

 
 

 

Summary of Contents for 63898

Page 1: ...ary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data...

Page 2: ...f you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most r...

Page 3: ...able must be replaced with a new one This work may only be carried out by an electrician The voltage of 230 V AC indicated on the nameplate of the device must match the existent mains voltage Never li...

Page 4: ...d or severe injuries Keep all safety precautions and instructions for future use Technical specifications Power W 800 Voltage V 220 240 Frequency 50 Pumping width m 90 Pumping head m 9 Max flow rate m...

Page 5: ...https www XPOtool com Item 63898 Page 5 The Tool Experts 12 2022 1 Figures Figure 1 Dimensions in mm Figure 2 Spare parts...

Page 6: ...outlet check valve is required Install an additional manual check valve for repair suggestion There must a minimum distance of 17 cm between the drain and floor when you use the side inlet Use a filte...

Page 7: ...https www XPOtool com Item 63898 Page 7 The Tool Experts 12 2022 1 Figure 5 Inlet covers covers for non use of inlets Figure 6 Optional intake for additional equipment Figure 7 Fixations...

Page 8: ...utlet non return valve Attention The non return valve being only 1 2 cm in size avoid inserting it too far Figure 9 Repair Open the upper repair flap to repair the ventilation switch and to take the b...

Page 9: ...https www XPOtool com Item 63898 Page 9 The Tool Experts 12 2022 1...

Page 10: ...https www XPOtool com Item 63898 Page 10 The Tool Experts 12 2022 1 Figure 10 Heads and draws Figure 11 Flow rates...

Page 11: ...98 Page 11 The Tool Experts 12 2022 1 Figure 12 Distance to wall The minimum size between the outlet of the toilet and rear wall is 255 mm Figure 13 Elbow fittings We recommend two 45 elbow fittings i...

Page 12: ...t be a second toilet above the level of backed up water The product must be fastened to the floor to avoid any lifting or turning Use and warning notices In case you are not at home for a longer time...

Page 13: ...welded connections To avoid that vibrations be transferred to the building it must be made sure that the piping is installed in a fixed manner and that all connection pieces can neither move nor get i...

Page 14: ...level reaches the starting value Power failure Re establish power Fuse blown if a new fuse blows immediately either the wire or the motor is defective Replace fuse if the cable or mo tor is defective...

Page 15: ...from the lifting sta tion but water is being pumped out Foreign body hitting impeller or macerator Remove foreign bodies Bad smell coming from the tank Carbon filter dirty Replace carbon filter The wa...

Page 16: ...on and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal d...