Introduction

 

 

Thank you for choosing to purchase this quality product. To minimise the risk of injury, we ask you to 
always take some basic safety precautions when using this product. Please read this operating manual 
carefully and make sure that you understand it.

 

Keep these operation instructions in a safe place.

 

 
 

Safety instructions

 

 

 CAUTION:

 

The  device  is  not  intended  for  use  by  persons  (including  children)  with  impaired  or  limited  physical, 
sensory, and mental abilities or lack of experience and/or real knowledge, unless they are supervised 
by a person responsible for their safety or follow the instructions made by this person on how to correctly 
use the device. Children should be supervised to ensure that they do not play with the device.

 

 
 

Product description

 

 

The  toilet  waste  water  pump  consists  of  a  housing,  a  motor,  and  a  pump.  The  pump  is  suitable  for 
domestic sewage and sanitary facilities. The system automatically switches the pump on and off de-
pending on the liquid level.

 

 

 Attention!

 

 

Perform a visual inspection of the device before every use. Do not use the device if the safety 
appliances are damaged or worn out. Never override safety regulations.

 

 

Only use the device accordingly to the intended purpose stated in this manual.

 

 

You are responsible for the safety of the working zone.

 

 

If the cable or the plug is damaged due to external influences, the cable must not be used. The 
cable must be replaced with a new one. This work may only be carried out by an electrician.

 

 

The  voltage  of  230

 

V  AC  indicated  on  the  nameplate  of  the  device  must  match  the  existent 

mains voltage.

 

 

Never lift, carry, or fix the device by using the power cable.

 

 

Make sure that the electrical plug connection is protected from flood and moisture. Always un-
plug the device before working on it.

 

 

Avoid exposing the device to direct jets of water.

 

 

The user is responsible for complying with local safety and mounting regulations. Ask an elec-
trician, if necessary.

 

 

The user must take appropriate measures (e.g., installation of an alarm system, a reserve pump, 
etc.) to prevent damage caused by the flooding in case of device malfunctioning.

 

 

In case of device failure, repairs can only be carried out by an electrician. No responsibility is 
accepted for damage caused by improper maintenance or use.

 

 

The device must never run dry or be operated with its suction line fully closed. The manufac-
turer’s warranty is void for damage to the device caused by dry running.

 

 

Do not use this device to operate swimming pools.

 

 

This device must not be integrated into any kind of domestic water circuit meant for potable 
water.

 

 

Pumping aggressive liquids and abrasive substances must always be avoided.

 

 

The pump must be protected from frost and it must be made sure that it cannot run dry.

 

 

The device must not be installed in septic tanks or pump shafts.

 

 

Avoid that chemical solvents, strong acids, or bases enter the device.

 

 

Only dispose of your toilet paper, faeces, and waste water via the device. Any other kind of 
waste must not be thrown into the toilet.

 

 

Avoid that too much hair enters the device.

 

 

Summary of Contents for 63898

Page 1: ...ary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data...

Page 2: ...f you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most r...

Page 3: ...able must be replaced with a new one This work may only be carried out by an electrician The voltage of 230 V AC indicated on the nameplate of the device must match the existent mains voltage Never li...

Page 4: ...d or severe injuries Keep all safety precautions and instructions for future use Technical specifications Power W 800 Voltage V 220 240 Frequency 50 Pumping width m 90 Pumping head m 9 Max flow rate m...

Page 5: ...https www XPOtool com Item 63898 Page 5 The Tool Experts 12 2022 1 Figures Figure 1 Dimensions in mm Figure 2 Spare parts...

Page 6: ...outlet check valve is required Install an additional manual check valve for repair suggestion There must a minimum distance of 17 cm between the drain and floor when you use the side inlet Use a filte...

Page 7: ...https www XPOtool com Item 63898 Page 7 The Tool Experts 12 2022 1 Figure 5 Inlet covers covers for non use of inlets Figure 6 Optional intake for additional equipment Figure 7 Fixations...

Page 8: ...utlet non return valve Attention The non return valve being only 1 2 cm in size avoid inserting it too far Figure 9 Repair Open the upper repair flap to repair the ventilation switch and to take the b...

Page 9: ...https www XPOtool com Item 63898 Page 9 The Tool Experts 12 2022 1...

Page 10: ...https www XPOtool com Item 63898 Page 10 The Tool Experts 12 2022 1 Figure 10 Heads and draws Figure 11 Flow rates...

Page 11: ...98 Page 11 The Tool Experts 12 2022 1 Figure 12 Distance to wall The minimum size between the outlet of the toilet and rear wall is 255 mm Figure 13 Elbow fittings We recommend two 45 elbow fittings i...

Page 12: ...t be a second toilet above the level of backed up water The product must be fastened to the floor to avoid any lifting or turning Use and warning notices In case you are not at home for a longer time...

Page 13: ...welded connections To avoid that vibrations be transferred to the building it must be made sure that the piping is installed in a fixed manner and that all connection pieces can neither move nor get i...

Page 14: ...level reaches the starting value Power failure Re establish power Fuse blown if a new fuse blows immediately either the wire or the motor is defective Replace fuse if the cable or mo tor is defective...

Page 15: ...from the lifting sta tion but water is being pumped out Foreign body hitting impeller or macerator Remove foreign bodies Bad smell coming from the tank Carbon filter dirty Replace carbon filter The wa...