Installation
Toilet connection
•
First put some silicone or liquid soap on the toilet port.
•
Fit the supplied collar onto the escape of the bowl.
•
Pull the rubber lip over the toilet port.
•
Position the hose clamp over the edge of the rubber lip and tighten it with a screwdriver.
•
After the device has been set up, fasten it to the floor with the two screws supplied.
•
If you are using the two floor mounting brackets, attach them to the floor before aligning the
device.
Warning!
No water should drip from the toilet cistern or other sanitary facilities. If so, the unit will
repeatedly be activated while draining the water. Therefore, always check if the tap or flush is turned off
completely after use.
Drain pipe connection
Insert the outlet elbow into the rubber outlet pipe. Turn it in the desired direction and fasten it with the
metal hose clamp supplied (36–50
mm). Then connect the hose using the 20–32
mm metal hose clamp,
being careful not to kink the hose. A 22–32
mm plastic reducer is provided if a 32
mm drain line is to be
installed.
Technical advice on drain pipes
•
Horizontal pipes must have a gradient of at least 1:200 (5
mm
⁄
m
) to the floor shaft.
•
If a vertical lift is required, this must be done before the horizontal run at the beginning of the
pipe run.
•
We recommend installing a drainage point so that the drain pipe can be drained before mainte-
nance work.
•
If the drain line is significantly lower than the unit, the resulting siphoning effect can suck out the
water seal in the unit. Installing an air inlet valve at the highest point of the pipeline solves this
problem.
•
The drainage pipes must be connected to the floor shaft with a suitable flange.
•
Make sure that all external piping is sufficiently insulated to prevent possible freezing.
Note!
Every angle on the pressure line of the system generates frictional losses (about 50
cm per angle
piece must be deducted from the technical data for vertical conveyance).
Always use even angles (or 2 45° elbows) and no 90° elbows.
Electrical supply connection
•
The electrical installation should be carried out by a specialist.
•
The device should be connected to a fully earthed electrical supply.
cm