background image

 

https://www.XPOtool.com 

 

Item 63489

 

Page 15

 

The Tool Experts

 

 

  

 

10 2022-1

 

 

Regulations for waste disposal

 

 
 

The Waste Electrical and Electronic Equipment Directive (WEEE Directive, 2012/19/EU) of the EU was 
implemented in the German law related to electrical and electronic equipment and appliances.

 

 

All WilTec electric devices that fall under the WEEE directive are labelled with the symbol of a crossed-
out wheeled rubbish bin. This symbol indicates that this electric device must not be disposed of with the 
domestic waste.

 

 

WilTec  Technik  GmbH  is  registered  with  the  German  registration  authority  EAR  (Stiftung  Elektro-
Altgeräte Register) under the WEEE-registration number DE45283704.

 

 

Disposal of used electrical and electronic devices (in-
tended for use in the countries of the European Union 
and  other  European  countries  with  a  separate  waste 
collection system for these devices).

 

The symbol on the packaging or the product itself indi-
cates that this product must not be treated as normal 
domestic waste but must be disposed of at a recycling 
collection station for electrical and electronic waste.

 

By disposing of this product correctly, you contribute to 
the protection of the environment and the health of your 
fellow people. Inappropriate disposal threatens the en-
vironment and health.

 

 

Material recycling helps to reduce the consumption of raw materials.

 

 

Additional information about the recycling of this product can be provided by your local commune, the 
municipal waste disposal facilities, or the store where you purchased the product.

 

 
 
 
 

Address:

 

WilTec Wildanger Technik GmbH

 

Königsbenden 12 / 28

 

52249 Eschweiler Germany

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Important Note:

 

 

Reproduction and any commercial use (of parts) of this operating manual, requires a written permission 
of WilTec Wildanger Technik GmbH.

 

Summary of Contents for 63489

Page 1: ...lar may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Page 2: ...If you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Ge...

Page 3: ...zone If the cable or the plug is damaged due to external influences the device must not be used The cable must be replaced with a new one first This work may only be carried out by an electrician The voltage of 230 V AC 50 Hz indicated on the type plate of the device must match the exist ent mains voltage The socket used must have a minimum distance of 1000 mm to the shower or bathtub Never lift c...

Page 4: ... might cause an electric shock a fire and or severe injuries Keep all safety precautions and instructions for future use Instructions having the note Attention call your attention to errors that may impair the correct operation of the device Technical specifications Power W 250 Voltage V 220 240 Frequency 50 Max lifting height m 7 Max delivery width m 70 Max water temperature 65 Max flow rate ℓ mi...

Page 5: ...https www XPOtool com Item 63489 Page 5 The Tool Experts 10 2022 1 Figures Figure 1 Dimensions in mm Figure 2 Spare parts ...

Page 6: ...allation An outlet check valve is required Install an additional manual check valve for repair suggestion The minimum distance between drain and floor must be 11 cm Use a filter in the shower and toilet to prevent hair from getting into the device Figure 4 Connections Min cm Max cm ...

Page 7: ...https www XPOtool com Item 63489 Page 7 The Tool Experts 10 2022 1 Figure 5 Optional intake for additional equipment Cover all intakes that are not used Figure 6 Fixations ...

Page 8: ... com Item 63489 Page 8 The Tool Experts 10 2022 1 Figure 7 Outlet 23 mm 28 mm non return valve The non return valve being only 1 2 cm in size avoid inserting it too far Figure 8 Heads and draws m m m m m m Max m m m m m ...

Page 9: ...https www XPOtool com Item 63489 Page 9 The Tool Experts 10 2022 1 Figure 9 Flow rates l min H m ...

Page 10: ... com Item 63489 Page 10 The Tool Experts 10 2022 1 Figure 10 Distance The minimum distance beneath the shower is 150 mm Figure 11 Elbow fittings We recommend two 45 elbow fittings instead of one 90 elbow fitting Min cm ...

Page 11: ...nection Functional principle The device is designed to pump wastewater from toilets and other sanitary facilities It consists of an electric pump D automatically controlled by a float switch C The emptying process is triggered like with a conventional toilet by pressing the flush see fig B A C D E G F ...

Page 12: ...to kink the hose A 22 32 mm plastic reducer is provided if a 32 mm drain line is to be installed Technical advice on drain pipes Horizontal pipes must have a gradient of at least 1 200 5 mm m to the floor shaft If a vertical lift is required this must be done before the horizontal run at the beginning of the pipe run We recommend installing a drainage point so that the drain pipe can be drained be...

Page 13: ...el is reached in the housing The overheating protection of the motor is switched on as soon as the motor is overheated Pull the plug out of the socket and plug it in again After a waiting time of around 30 60 min the device will work normally again If the power fails connected water sources must not be operated before power is restored to avoid malfunction Warning The device is only suitable for t...

Page 14: ...repair Membrane gear wheel dam aged or pump partially ob structed After complete draining motor is re starting several times before going off Water backflow towards pump backflow valve not working properly Flush once or twice with clean water to free valve Remove and clean valve Motor emitting a loud noise yet pump is not draining water motor is not being switched off Backflow from drain pipes or ...

Page 15: ...ion and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the protection of the environment ...

Reviews: