background image

 

https://www.XPOtool.com 

 

Item 63021

 

Page 3

 

The Tool Experts

 

 

  

 

05 2022-1

 

 

Introduction

 

 

Thank you for choosing to purchase this quality product. To minimise the risk of injury, we ask you to 
always take some basic safety precautions when using this product. Please read this operating manual 
carefully and make sure that you understand it.

 

Keep these operation instructions in a safe place.

 

 
 

Safety instructions

 

 

 Attention:

 

 

When you smell gas:

 

 

 

close gas supply.

 

 

extinguish open flames.

 

 

With gas smell persisting, immediately call gas supplier and fire brigade.

 

 

 

Never  store  or  use  petrol  or  other  highly  flammable  vapours  and  liquids  near  this  device  or 
similar devices.

 

 

A disconnected liquid gas cylinder must not be stored near this device or comparable devices.

 

 

Only suitable for outdoor use or in very well-ventilated areas. In such an area, at least a quarter 
of its total surface must be open. The total surface of an area is the total of its wall surfaces.

 

 

 

 

 

Improper installation, adjustment, structural changes, maintenance, or care can cause property 
damage or injuries. Read the assembly, operation, and maintenance instructions carefully and 
completely before you start using the device.

 

 

The device and gas cylinder must be set up in accordance with the applicable regulations.

 

 

The ventilation slots in the gas cylinder housing must not be blocked.

 

 

The device must not be moved while in operation.

 

 

Gas lines and hoses must be replaced within the prescribed periods.

 

 

Only gas and gas cylinders corresponding to the manufacturer’s instructions may be used.

 

 

A space with a maximum diameter of 29

 

cm and a height of 70

 

cm is available in the heater for 

the gas cylinder (not included in the scope of delivery). In strong winds, special care must be 
taken to ensure that the heater cannot fall over. The distance between the device and the gas 
cylinder must be at least 1

 

m.

 

 

The injector of this device cannot be removed, it is only connected at the factory. It is forbidden 
to modify the device in such a way that it works at a pressure other than the set pressure.

 

 

Do not connect the gas cylinder directly to the device without interposing a pressure reducing 
valve. Only use the gas and the type of gas cylinder specified in the instructions.

 

 

The pressure reducing valve must match the respective device type in accordance with DIN 
EN16129:2013 and national standards:

 

 

A 30

 

mbar pressure reducing valve is used for butane/propane of category I3BP(30).

 

 

A 30

 

mbar pressure reducing valve is used for butane of category I3+(28–30/37).

 

 

A 37

 

mbar pressure reducing valve is used for propane of category I3+(28–30/37).

 

Summary of Contents for 63021

Page 1: ...vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data...

Page 2: ...f you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most r...

Page 3: ...cylinder must be set up in accordance with the applicable regulations The ventilation slots in the gas cylinder housing must not be blocked The device must not be moved while in operation Gas lines a...

Page 4: ...d the pilot flame burner must be checked for leaks or damaged areas The leak test should be carried out with a soap solution Never use an open flame to look for leaks Do not put the heater into operat...

Page 5: ...pressure reducing valve and hose must correspond to the local regulations The installation must also comply with local requirements if there are none it must meet the standard requirements for the st...

Page 6: ...at the lower end of the flame protection grille must be pushed to the side to the left or right of the control unit If the pilot flame does not ignite or goes out again repeat step 3 4 After igniting...

Page 7: ...or stainless steel Gas hose connections with metal hose clamps screw caps for Germany Heat radiation from reflector Technical specifications Gas to be used only propane butane or their mixture Max po...

Page 8: ...Injector size I3 28 30 37 Butane 28 30 13 G30 945 g h G31 929 g h 1 90 main burner 0 18 pilot burner Propane 37 I3B P 30 Butane propane or their mixtures 30 I3B P 50 50 1 70 main burner 0 18 pilot bur...

Page 9: ...m adjustable spanner 2 23 cm slip joint pliers Philips screwdriver with medium blade Spray bottle of soap solution for leak test Figures Name Qty A Reflector panel 3 B Reflector plate 1 FF Reflector s...

Page 10: ...ector spacer 3 GG HH II JJ KK LL 8 washer 9 6 washer 9 M6 10 screw 9 Cap nut 9 Wing nut 3 Wrench 1 Assembly Step 1 1 Put the 3 post brackets 1 on each position on the stand 2 as shown 2 Use 3 M8 16 bo...

Page 11: ...urner are assembled according to instructions and all bolts and nuts are tightened 2 Put 6 large flat washers on the 3 reflector spac ers 1 Step 6 Fasten the reflector 2 with 3 large flat washers and...

Page 12: ...ontaminated areas ose connections Re tighten connections Defective heat sensor Replace heat sensor eaking gas line Check connections Insufficient fuel pressure Container almost empty refill Burner doe...

Page 13: ...on and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal d...