Maintenance guidelines
This submersible pump is a certified quality product that is subject to a strict final inspection. We recom-
mend a regular inspection and maintenance to ensure a longer lifespan of the device and an interruption-
free operation.
Important instructions!
•
Properly disconnect the pump from its power supply by removing its plug from the socket before
performing any kind of maintenance work.
•
In case of the pump being transported or moved around a lot, it is advised to clean it with clear
water after every use.
•
In case of the pump remaining stationary for a longer time, the function of its lock switch should
be checked every 3
months.
•
Fibrous material that might have accumulated within the housing of the pump should be re-
moved with water.
•
Every 3
months, the shaft bottom should be freed from mud.
•
Remove the residues on the float switch with clear water.
Cleaning the impeller
If there are excessive residues collected in the pump casing, the bottom part of the pump needs to be
demounted the following:
1.
Remove the suction cage from the housing of the pump.
2.
Clean the impeller with clear water.
Important!
The pump must not be placed or supportes on the impeller.
3.
Follow the previous steps in a reverse order to reassemble the pump.
Setting the switch-point
Fix the cable of the float switch to the cable clip found on the casing of the pump to set the desired
switch-on and switch-off height.
•
The float switch is installed so that the switch-on and switch-off point can be reached without
any problem. To check this, place the pump into a container filled with water, carefully lift the
float switch by hand and lower it again. By doing so, see if the pump switches itself on and off.
•
To make sure that the pump switches itself on and off properly, the length of the cable comprised
between the float switch and fixing clip must be of a minimum of 10
cm.
•
When setting the float switch, make sure that the water has a minimum level of 15
mm to prevent
the pump from running dry.