Range of application

 

 

This submersible pump is usually installed in basements. There, it grants protection from flooding. Ad-
ditionally, the pump can be used, where water needs to be transported from one spot to another, e.g., 
at home, in agriculture, in gardening, for sanitary work and so forth.

 

 
 

Resistance

 

 

 

The maximum temperature of the pumped liquid should not 35

 

 in continuous oper-

ation.

 

 

The pump must not be used to pump flammable, gassing, or explosive liquids.

 

 

The pump must not be used to pump other liquids, especially motor fuels, cleaning agent, or 
other chemical products.

 

 
 

Installation

 

 

The pump is installed the following way: in a fixed position either with fixed or flexible tubing.

 

 

Attention!

 

 

When installing the pump, make sure not to freely suspend it with its pressure line or power 
cable. The submersible motor pump needs to be hung up by the appropriate handle or placed 
on the floor of the shaft.

 

 

To ensure the impeccable functioning of the pump, the shaft floor needs to be kept free of mud 
and dirt of any kind.

 

 

If the water level is too low, the mud on the shaft floor might quickly dry and hinder the pump 
from starting. It is therefore necessary to regularly check the pump (by performing tests before 
operation).

 

 

The float switch is adjusted to allow the pump to start immediately.

 

 

Note: 

The pump shaft should have a minimum size of 40×40×50

 

cm, so that the floater can move freely.

 

 
 

Mains connection

 

 

The pond pump that you have purchased is already equipped with a protection plug. The pump is meant 
to be connected to a 220/230

 

V~50

 

Hz safety socket. Make sure that the socket is sufficiently protected 

(min. 6

 

A) and fully functional. Plug in the plug, the pump is operational.

 

 

Note:

 

If the cable or the plug is damaged due to external influences, the cable must not be repaired. It 

must be replaced with a new one. This work can only be carried out by an electrician.

 

 
 

Operation settings

 

 

After carefully reading all information and instructions contained within this operation manual, the pump 
can be operated by abiding the following steps:

 

 

Check if the pump is resting on the bottom of the shaft.

 

 

Check if the pressure line is properly attached.

 

 

Check if the electric source has 230

 

V~50

 

Hz.

 

 

Check if the socket is in a good condition.

 

 

Make sure that the electrical connections and circuits are sufficiently protected from moisture 
and water.

 

 

Do not allow the pump to run dry.

 

 

 

Summary of Contents for 62935

Page 1: ...y depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data ma...

Page 2: ...ts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH K nigsbenden 12 52249 E...

Page 3: ...e damaged or worn out Never override safety regulations Only use the device accordingly to the intended purpose stated in this manual You are responsible for the safety of the working zone If the cabl...

Page 4: ...the mud on the shaft floor might quickly dry and hinder the pump from starting It is therefore necessary to regularly check the pump by performing tests before operation The float switch is adjusted t...

Page 5: ...clear water Cleaning the impeller If there are excessive residues collected in the pump casing the bottom part of the pump needs to be demounted the following 1 Remove the suction cage from the housi...

Page 6: ...floor Insufficient flow Inlet filter clogged Clean inlet filter Reduced pumping performance due to dirty water or water con taining abrasive material Clean pump and replace worn parts The pump switche...