background image

 

https://www.XPOtool.com 

 

Item 62553

 

Page 7

 

The Tool Experts

 

 

  

 

05 2022-1

 

e)

 

Compare the two voltages with the yellow table printed in the display (“STARTER TEST”). The 

upper table row refers to the “LOAD VOLTS,” i.e., the voltage measured during the load test 

with the unit. Below this voltage value, the table shows the corresponding minimum starting 

voltage (“MIN. CRANK VOLTS”).

 

 

Example: You measure a voltage of 10.4

 

V during the load test and the voltage collapses to 9.5

 

V during 

starting. According to the table, a starting voltage of up to 8.2

 

V is acceptable. The starter engine is all 

right. If a starting voltage of less than 8.2

 

V is measured, a short circuit in the starter, a fixed bearing in 

the starter, etc. could be the reason for excessive power consumption.

 

 
 

Technical data

 

 

Dimensions (L×W×H)

 (

)

 

290 × 110 × 75

 

Ampere range

 (A)

 

300–1000

 

Testing procedure

 

100

 

A load current

 

Cable length

 (

)

 

2 × 30

 

Other

 

2

 

clamping pliers with 30

 

cm supply cable

 

 
 

Malfunctions on the device

 

 

If it can be assumed that safe operation is no longer possible, the device must be taken out of 

operation and secured against inadvertent operation.

 

 

This applies if

 

 

 

the unit shows visible damage.

 

 

the device is no longer functional.

 

 

parts of the unit are loose or loose.

 

 

the connecting cables show visible damage.

 

 

Summary of Contents for 62553

Page 1: ...he operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ in...

Page 2: ...avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec de...

Page 3: ...r paper away from the unit Do not install the unit in a place where it is exposed to high humidity or vibrations The device is intended for use in dry and clean rooms If condensation forms wait up to...

Page 4: ...or eye drops without doc tor s instructions Things to know about rechargeable lead acid batteries The efficiency of a lead acid battery decreases as temperatures fall A fully charged battery has only...

Page 5: ...old test current is printed on the battery use the table below to select the appropriate scale Battery capacity Ah Cold test current CCA A 36 44 200 55 66 400 75 88 600 95 110 800 180 1000 3 Press the...

Page 6: ...the charging system With the help of the battery tester many small general faults in the charging circuit can be quickly and easily detected The motor should be at normal operating temperature for te...

Page 7: ...V is acceptable The starter engine is all right If a starting voltage of less than 8 2 V is measured a short circuit in the starter a fixed bearing in the starter etc could be the reason for excessiv...

Page 8: ...ate collec tion system for these devices The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling col...

Reviews: