Introduction

 

 

Thank you for purchasing this quality product.

 To minimise the risk of injury we urge that our clients 

take some basic safety precautions when using this device. Please read the operation instruc-

tions carefully and make sure you have understood its content.

 

Keep these operation instructions safe.

 

 

Note! 

To ensure perfect condition and safe operation, the user must observe and comply with the safety 

and warning instructions in these instructions.

 

 
 

Intended use

 

 

The intended use of the device is to test 6

 

V and 12

 

V batteries and accumulators. Any other use than 

specified is not permitted!

 

 
 

Operating conditions/safety instructions

 

 

 

The device may only be operated at the voltage specified for it.

 

 

The operating position of the unit is horizontal and resting on the rubber feet so that the display 

points upwards.

 

 

It is essential to ensure that the technical specifications given in this manual are observed. Ex-

ceeding the specified values may cause damage to the unit or the object to be tested.

 

 

The unit must not be placed in the vicinity of strong high-frequency or magnetic fields, as this 

may cause the unit to enter an undefined operating state, resulting in incorrect test results.

 

 

Ventilation slits or vents prevent an excessive rise in temperature. Keep materials such as flam-

mable substances or paper away from the unit.

 

 

Do not install the unit in a place where it is exposed to high humidity or vibrations.

 

 

The device is intended for use in dry and clean rooms.

 

 

If condensation forms, wait up to 2

 

hours for the unit to acclimatise.

 

 

Protect the unit from moisture, splashes of water, and the effects of heat.

 

 

The unit must not be used in conjunction with highly flammable and combustible liquids.

 

 

This device may only be used by persons with limited physical, sensory, or mental abilities or a 

lack of experience or necessary expertise if they have been introduced to the use of the device 

by a competent person familiar with the device and responsible for them, and if they are super-

vised by this person.

 

 

Children must not use the device and must be supervised in its vicinity to ensure that they do 

not play with the device.

 

 

Do not operate the assembly in an environment where flammable gases, vapours, or dust are 

present.

 

 

Repairs may only be carried out by a trained electrician. Only original spare parts may be used 

for repairs. The use of different spare parts can lead to serious damage to property and personal 

injury.

 

 

The unit must always be disconnected from the test object before use.

 

 

Before commissioning, always check if the unit or assembly is suitable for the desired applica-

tion. In case of any uncertainties or questions, contact a specialist.

 

 
 

Product features and description

 

 

 

Portable

 

 

No external power supply required

 

 

Tests can be completed in a short time

 

 

Impact resistant

 

 

No annual calibration required

 

 

Copper-plated high performance terminal blocks

 

 

Ventilated

 

Summary of Contents for 62553

Page 1: ...he operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ in...

Page 2: ...avoided If you should find a mistake or wish to make a suggestion for improvement we look forward to hearing from you Send an e mail to service wiltec info or use our contact form https www wiltec de...

Page 3: ...r paper away from the unit Do not install the unit in a place where it is exposed to high humidity or vibrations The device is intended for use in dry and clean rooms If condensation forms wait up to...

Page 4: ...or eye drops without doc tor s instructions Things to know about rechargeable lead acid batteries The efficiency of a lead acid battery decreases as temperatures fall A fully charged battery has only...

Page 5: ...old test current is printed on the battery use the table below to select the appropriate scale Battery capacity Ah Cold test current CCA A 36 44 200 55 66 400 75 88 600 95 110 800 180 1000 3 Press the...

Page 6: ...the charging system With the help of the battery tester many small general faults in the charging circuit can be quickly and easily detected The motor should be at normal operating temperature for te...

Page 7: ...V is acceptable The starter engine is all right If a starting voltage of less than 8 2 V is measured a short circuit in the starter a fixed bearing in the starter etc could be the reason for excessiv...

Page 8: ...ate collec tion system for these devices The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling col...