10 2022-1

 

 

Technical specifications

 

 

Item number

 

51545

 

51546

 

51547

 

Power supply

 

220–240

 

V / 50

 

Hz

 

Power consumption

 (W)

 

550

 

900

 

2200

 

Length of cable

 (m)

 

1

 

1

 

1

 

Sound level

 (dB (A))

 

72

 

72

 

78

 

Pressure range

 (

)

 

3.5

 

5.5

 

10.5

 

Rotation speed

 (rpm)

 

2900

 

2900

 

2850

 

Max. flow rate

 (

h

)

 

6000

 

7200

 

9000

 

Max. suction height

 (m)

 

9

 

9

 

9

 

Lifting height

 (m)

 

35

 

55

 

105

 

Max. temperature

 (

)

 

of pumped medium

 

60

 

60

 

60

 

of environment

 

40

 

40

 

40

 

 
 

Maintenance

 

 

 Our pumps do not require any special maintenance; however, we ask you to follow the following 

advice:

 

 

 Attention!

 

Before every maintenance, the pump must be switched off; to  do so, disconnect the  pump from the 
power supply.

 

 

 

Before a longer period of non-operation or winter storage, the pump must be rinsed thoroughly 
with water, emptied completely, and stored at a dry location.

 

 

In case of frost danger, the pump must be completely emptied.

 

 

After long non-operation periods, check if a proper turning of the rotor takes place by shortly 
switching the device on and off.

 

 
 

Technical drawing and parts list

 

 

 

Name

 

 

Name

 

 

Name

 

1

 

Driving wheel

 

5

 

Fan cover

 

9

 

Pump holder

 

2

 

Outlet

 

6

 

Bracket

 

10

 

Mechanic seal

 

3

 

Terminal box

 

7

 

Rotor system

 

11

 

Inlet housing

 

4

 

Fan

 

8

 

Wrapped stator

 

12

 

Pressure plug

 

 

Summary of Contents for 51545

Page 1: ...ar may vary depending on model Please read and follow the operating instructions and safety information prior to initial operation Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments ...

Page 2: ...ly If you have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler...

Page 3: ...turn valve The pump must not be immerged into water The water is sucked in via a hose Prime the pump and suction line with water before using it otherwise it will run the risk of running dry Check if there is a water column prime the pump with water before use until the water column is present to 100 Assembly The pump must be set up on a level and firm surface The end of the suction line should be...

Page 4: ... spray nozzles etc in the pressure line must be completely open so that the air in the suction line can escape freely 7 Depending on the suction height and air quantity in the suction line the first suction process can take some time With longer suction periods of sucking in new water should be refilled 8 If the pump is removed after its use do not forget that it must be refilled with water before...

Page 5: ...however we ask you to follow the following advice Attention Before every maintenance the pump must be switched off to do so disconnect the pump from the power supply Before a longer period of non operation or winter storage the pump must be rinsed thoroughly with water emptied completely and stored at a dry location In case of frost danger the pump must be completely emptied After long non operati...

Page 6: ...https www XPOtool com Item 51545 51547 Page 6 The Tool Experts 10 2022 1 Max m cm ...

Page 7: ...Has the suction depth been exceeded Engine does not run Cause Solution Lack of voltage Check voltage Pump impeller blocked thermo controller has switched pump off Dismantle and clean pump Pump does not suck in Cause Solution Suction valve not in the pumped medium Install suction valve inside the water Pump room without water Fill in pump medium in suction nozzle Air in suction line Check if suctio...

Page 8: ...uction strainer dirty Clean suction basket Water level drops rapidly Lower suction valve Pump capacity reduced because of harmful sub stances Clean pump and replace worn parts Thermo switch switches off pump Cause Solution Engine overloaded excessive friction due to for eign particles Dismantle and clean pump prevent sucking in of foreign matter Filter ...

Page 9: ...Union and other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the protection of the environmen...