background image

28

GUARANTEE

Terms and Conditions for UK & ROI (outside UK & ROI contact your local distributor)

We, Applied Energy Products, guarantee this product against faulty workmanship and material defects for a period 
of  5 years  from  the  date  of  purchase subject  to  regular  servicing  by  by  Applied  Energy  Products  Limited, or  our 
approved agents. 

In the event of a product breakdown during the guarantee period, you should initially contact your installer, before 
contacting Applied Energy Products on the Technical line number below providing that:

a) The product has been installed in a residential or light commercial environment. 

b) The  product  has  been  correctly  installed  and  commissioned  in  accordance  with  our  instructions  and  is  being 

used on the supply circuit or voltage printed on the rating plate.

c) The product has been used in accordance with these instructions and has not been tampered with or otherwise 

subject to misuse, neglect or accident.

d) The  product  has  been  regularly  maintained  in  accordance  with  these  instructions  and  the  airway  is 

unobstructed.

e) The product has not been taken apart, modified or repaired except by a person authorised by us.

f) Evidence of the date of purchase in the form of an invoice or receipt will be required in order to qualify under the 

terms of this guarantee.

g) For  the  service  work  to  be  undertaken  free  of  charge,  the  work  must  only  be  undertaken  by  Applied  Energy 

Products Limited, or our approved agents.

h) Service  under  guarantee  has  no  effect  on the  expiry date.  The  guarantee  on  any  exchanged  parts  or  product 

ends when the original guarantee period ends.

i)

In  the  event  of  a  product  being  returned  to  Applied  Energy  Products  Limited  and  not  found  to  be  faulty,  the 
product  would  be  available  for  collection  from  the  relevant  premises  within  one  month  and  if  not  collected  it 
would be disposed of or delivered by Applied Energy Products Limited and a delivery charge made

.

EXCLUSIONS

This guarantee does not apply to the repair or replacement of Filters, Accessories, Isolating switches, Electrical 
cable, Fuses and/or Circuit breakers or annual servicing.

This guarentee covers products supplied by Applied Energy Products only and does not cover other products and 
components used to create a system that have not been purchased from Applied Energy Products.

The responsibility for the suitability of the complete system for the specific application remains the responsibility of 
the original specification engineer.

This guarantee does not cover damage or defects arising from poor or incorrect installation, improper use or lack of 
maintenance. It is the responsibilty of the installer to check that the installation parameters meet the requirements 
of the product, and any relevant regulations.

If we are called out to a fault, which is subsequently identified as being an installation fault, we will make a charge. 
It is important that the routine checks are completed before calling us out, as many issues can be simply diagnosed 
and resolved.

We make no guarantees as to response times for repairs. We will endeavour to achieve the most timely response 
possible but while we indicate an average response time, this should not be taken as a guarantee.

The guarantee applies to a repair or replacement (at our discretion) of the product subject to the conditions above, 
and does not cover compensation for the loss of the product or consequential loss of any kind.

This guarantee does not affect your statutory rights.

Booklet 23515AA Rev. A

Applied Energy Products Limited
Morley Way
Peterborough
PE2 9JJ

Customer Care / Technical Line: 0844 372 7766
Customer Care / Technical Fax:  0844 372 7767
Sales Line:       

0844 372 7750

Sales Fax         

0844 372 7760 

www.applied-energy.com

Xpelair is a registered trademark of Applied Energy 
Products Limited.
Applied  Energy  Products  reserve  the  right  to  alter 
product  specifications  or  appearance  without  prior 
notice. All finishes and diagrams in this booklet are 
as accurate as printing processes allow.

Summary of Contents for Xcell 150 QV

Page 1: ...1 Installation and Operating Instructions Xcell 150 QV Xcell 150 QVW Mechanical Ventilation Unit with Heat Recovery Please ensure these instructions are kept safe and accessible at all times...

Page 2: ...ction of a voltmeter 9 6 4 Factory speed settings 9 6 5 Technical data 10 6 6 Applied Energy accessories for manual or automatic operation 10 6 7 Applied Energy spares available 10 7 Electrical Wiring...

Page 3: ...luding children and the infirm with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the app...

Page 4: ...l air is blown into the house and the cooled exhaust air is ducted out of the building There are numerous accessories available for controlling the MVHR see section 6 6 4 3 MVHR installation planning...

Page 5: ...s MVHR must not be fitted in rooms or areas of the house with strong odours which could then permeate into the MVHR and contaminate the fresh air supplied from the MVHR The following criteria must als...

Page 6: ...supplied with the MVHR can be fitted to the front or the rear and therefore the duct connections can be deter mined on site See the diagram below for the left hand duct connections Right handed instal...

Page 7: ...be used for final connections with special care taken to avoid restrictions and other conditions which will restrict air flow 5 6 Condensate drain A condensate drain must be fitted to run to the build...

Page 8: ...8 5 8 Installation dimensions...

Page 9: ...ir speed 1 red pot S2 Supply air speed 2 blue pot and S 2 Exhaust air speed 2 red pot S3 Supply air speed 3 blue pot and S 3 Exhaust air speed 3 red pot Turning the potentiometer to the right increase...

Page 10: ...e flush or surface mounted QHS sensor 96009AA The Humidistat sensor is suitable for the Xcell 150 QVW model only Note 1 When using Humidistats in conjunction with the Q3SP 3 speed switch a maximum of...

Page 11: ...oller Xcell 150 QV Internal Terminals Green Yellow Brown Blue Bl Bn G Y 1 Phase 220 240Vac 50 60Hz N Fuse L N E N L L Bn Bl G Y 10 V O P 0V Fused Switch Spur By Others MS2 Controller 23513AW 10V O P 0...

Page 12: ...5 open Jp6 closed Jp7 open Jp8 closed Jp9 open Jp10 open Fused Switch Spur By Others AEP Ref Xcell 150 04e a Q3SP Controller 96005AA Green Yellow Brown Blue 1 Phase 220 240 Vac 50 60Hz Fuse L N E Bn B...

Page 13: ...p7 open Jp8 closed Jp9 open Jp10 closed Transformer G ree n Ye llow B ro wn B lue 1 Phase 220 240 Vac 50 60Hz Fuse L N E Bn Bl G Y Fused Switch Spur By Others N L AEP Ref Xcell 150 03e a QCO Controlle...

Page 14: ...Controller 96005AA QHS Controller 96009AA QCO Controller 96003AA QHS Controller 96009AA QHS Controller 96009AA Fused Switch Spur By Others Green Yellow Brown Blue 1 Phase 220 240 Vac 50 60Hz Fuse L N...

Page 15: ...Q3SP Controller 96005AA QHS Controller 96009AA QHS Controller 96009AA QHS Controller 96009AA QHS Controller 96009AA Fused Switch Spur By Others Green Yellow Brown Blue 1 Phase 220 240 Vac 50 60Hz Fuse...

Page 16: ...k succession to acknowledge reset is complete Fault alarm LEDs 1 2 3 flash every second Fault alarm reset Mains voltage briefly interrupted Settings MVHR On Press plus key MVHR Off Press minus key unt...

Page 17: ...d 3 is manually activated on the 3 speed switch the CO2 sensor is deactivated Switchpoints of the CO2 sensor 1 5 V MVHR switches from speed 2 to speed 1 900 ppm 5 0 V MVHR switches from speed 1 to spe...

Page 18: ...an will stop the exhaust air fan will remain on When the outgoing air temperature reaches 9 C again the supply air fan comes back on automatically Settings table Option Temperature outgoing air Temper...

Page 19: ...rrect positions in the MVHR Please note the clean side of the filter is placed next to the Heat Exchanger o Filters can be cleaned by gently knocking together to remove dust dirt Replace the Access Ha...

Page 20: ...out by a qualified service technician Contact details for authorised servicing by Xpelair approved technicians can be found on the back of this booklet 10 1 Fault locating table FAULT MALFUNCTION CHE...

Page 21: ...Remove the Heat Exchanger Retaining Bracket 6 Remove the Heat Exchanger carefully keeping it horizontal to avoid damaging the EPP housing 7 Remove the 4 off Terminal Cover retaining screws 8 Remove th...

Page 22: ...d is flat against the EPP housing l Secure the new fan into place with the 3 off retaining screws m Remove the string from the new fan leads n Connect the power and control leads of the new fan to the...

Page 23: ...23 11 Customer Notes to record details of filter recuperator cleaning etc...

Page 24: ...24 Customer Notes continued...

Page 25: ...25 Customer Notes continued...

Page 26: ...26 Maintenance Log Date Action Signature Stamp...

Page 27: ...27 This Xpelair MVHR was purchased from Supplier stamp On ________________________ date...

Page 28: ...ited and a delivery charge made EXCLUSIONS This guarantee does not apply to the repair or replacement of Filters Accessories Isolating switches Electrical cable Fuses and or Circuit breakers or annual...

Reviews: