Wire the Transformer 

MAKE SURE THE MAINS SUPPLY IS ISOLATED 

26. If surface mounting, route Low Volt (7V/12V ac) and mains supply cables through the appropriate knockouts into their

respective compartments. When using the side entries a hole suitable for the cable size should be made centrally in

the rectangular section.

27. Locate the cables in the cable clamps and make connections as shown in J. Ensure all connections are tight.

28. For fixed wiring circuits the protective fuse for the appliance must not exceed 5A.

29. Re-fit fuses and switch on supply.

Using the fan. 

LV100R / LV100S Only 

Operate the fan using the on/off switch (not supplied). Repeat to switch off.

LV100TR / LV100TS Only 

Operate the fan using an on/off switch (not supplied). Note – the fan may take up to 10 seconds to turn on once the

switch has been operated. When the switch is turned off, the fan continues to operate for the set time delay. To adjust

the over-run period, turn the transformer control “T” clockwise to increase and anti-clockwise to decrease – see Figure

H.

LV100PR / LV100PS Only 

Operate the fan by pulling and releasing the cord. Repeat to switch off.

LV100HTR / LV100HTS Only. 

The fan automatically adjusts to slow changes in natural humidity levels without operating the fan.  If the humidity

levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will not be triggered

by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than 5% RH in 5

minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable time delay.

LV100HPTR / LV100HPTS Only. 

Automatic mode

 - The fan automatically adjusts to slow changes in natural humidity levels without operating the fan.

If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will

not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than

5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable

time delay.

Pull Cord operation 

– Use the integral pull cord switch. When the fan is switched off, the fan continues to operate for

the adjustable time delay then goes into automatic mode.

LV100PIRR / LV100PIRS Only. 

The sensor detects movement in the room and activates the fan. When movement is sensed, the fan will run for a

pre-set overrun period and any further movement sensed will re-start the sequence. This ensures that the room is

only ventilated during and immediately after use. When the fan is first installed it will run for the time set by the over-

run timer. After this time, if no movement is sensed the fan will go into stand-by mode.

All Fans 

Re-fit the front cover by hooking in the top first, and then swing the cover down to clip into place. 

Cleaning (recommended once a month). 

1. Before cleaning, isolate the fan completely from the mains supply.

2. The fan should be periodically wiped clean in position with a damp, lint free cloth and mild

detergent.

3. Do not immerse the fan in water or other liquids to clean any other parts of the fan.

4. Do not use strong detergents, solvents or chemical cleaners

5. Allow fan to dry thoroughly before use.

6. Apart from cleaning, no other maintenance is required.

Disposal 

This product should not be disposed of with household waste. 
Please recycle where facilities exist. 
Check with your local authority for recycling advice. 

Summary of Contents for Simply Silent LV100R

Page 1: ...et before commencing installation Do install each fan with a means for disconnection in all poles in the fixed wiring Do make sure the mains supply is switched off before attempting to make electrical...

Page 2: ...gral pull cord switch In automatic mode the built in timer automatically operates the fan for a pre set delay time from 30 seconds to 30 minutes once humidity drops below the pre set Relative Humidity...

Page 3: ...Back plate fixing positions Front Cover Removal Depress Cover Latch with tool remove Cover A C B...

Page 4: ...Minimum 30 seconds Maximum 30 minutes Factory settings Timer 15 minutes RH 75 D E H F G...

Page 5: ...Wiring and setting up I1...

Page 6: ...ract Refer to Building Regulations for specific requirements Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric Requir...

Page 7: ...ated 2 core cable supply to transformer LV100R LV100S LV100PR LV100PS LV100HTR LV100HTS LV100HPTR LV100HPTS LV100PIRR LV100PIRS Suitably rated 3 core cable supply to transformer LV100TR LV100TS 1 Chec...

Page 8: ...e back plate to the wall ceiling using appropriate fasteners supplied See figure A 12 If using screws do not over tighten Mount the back draft shutter 13 Peel the backing from the foam strip supplied...

Page 9: ...ion LV100TR LV100TS LV100PIRR LV100PIRS only To adjust the over run period turn the control T clockwise to increase and anti clockwise to decrease see Figure H LV100HTR LV100HTS LV100HPTR LV100HPTS on...

Page 10: ...Automatic mode The fan automatically adjusts to slow changes in natural humidity levels without operating the fan If the humidity levels increase at a rate slower than 5 RH in 5 minutes up to the pre...

Page 11: ...This page has been left blank for the addition of any notes you may wish to make...

Page 12: ...or Glen Dimplex UK Ltd Glen Dimplex Europe Limited Millbrook House Grange Drive Hedge End Southampton SO30 2DF Airport Road Cloghran Co Dublin K67 VE08 Telephone 44 0 344 879 3588 Telephone 353 0 1 85...

Reviews: