background image

Xpelair Simply Silent

TM 

LV100 SELV Fan 

Installation and Maintenance Instructions 

LV100R (93011AW) / LV100S (93031AW)  

Standard

 

LV100TR (93012AW) / LV100TS (93032AW)  

Timer

 

LV100PR (93013AW) / LV100PS (93033AW)   

Pull Cord 

LV100HTR (93014AW) / LV100HTS (93034AW) 

Humidistat, Timer 

LV100HPTR (93015AW) / LV100HPTS (93035AW) 

Humidistat, Pull Cord, Timer 

LV100PIRR (93016AW) / LV100PIRS (93036AW)

  

Integral Body Movement Sensor 

D

o read the entire instruction leaflet before commencing installation.

Do install each fan with a means for disconnection in all poles in the fixed wiring.

Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any

maintenance or cleaning.

Please leave this leaflet with the fan for the benefit of the user. 

UK customers: 
If you have any queries before or after installing this product call the Xpelair Technical H44 (0) 

ϯϰϰϴϳϵϯϱϴϴ

ŽƌĞŵĂŝůĐƵƐƚŽŵĞƌ͘ƐĞƌǀŝĐĞƐΛŐůĞŶĚŝŵƉůĞdž͘ĐŽŵ

 Our engineers are there to help you during normal office hours. Customers

outside the UK should contact your local Xpelair distributor. 

     LV100 Range Round Fan

     LV100 Range Square Fan

Summary of Contents for Simply Silent LV100R

Page 1: ...et before commencing installation Do install each fan with a means for disconnection in all poles in the fixed wiring Do make sure the mains supply is switched off before attempting to make electrical...

Page 2: ...gral pull cord switch In automatic mode the built in timer automatically operates the fan for a pre set delay time from 30 seconds to 30 minutes once humidity drops below the pre set Relative Humidity...

Page 3: ...Back plate fixing positions Front Cover Removal Depress Cover Latch with tool remove Cover A C B...

Page 4: ...Minimum 30 seconds Maximum 30 minutes Factory settings Timer 15 minutes RH 75 D E H F G...

Page 5: ...Wiring and setting up I1...

Page 6: ...ract Refer to Building Regulations for specific requirements Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric Requir...

Page 7: ...ated 2 core cable supply to transformer LV100R LV100S LV100PR LV100PS LV100HTR LV100HTS LV100HPTR LV100HPTS LV100PIRR LV100PIRS Suitably rated 3 core cable supply to transformer LV100TR LV100TS 1 Chec...

Page 8: ...e back plate to the wall ceiling using appropriate fasteners supplied See figure A 12 If using screws do not over tighten Mount the back draft shutter 13 Peel the backing from the foam strip supplied...

Page 9: ...ion LV100TR LV100TS LV100PIRR LV100PIRS only To adjust the over run period turn the control T clockwise to increase and anti clockwise to decrease see Figure H LV100HTR LV100HTS LV100HPTR LV100HPTS on...

Page 10: ...Automatic mode The fan automatically adjusts to slow changes in natural humidity levels without operating the fan If the humidity levels increase at a rate slower than 5 RH in 5 minutes up to the pre...

Page 11: ...This page has been left blank for the addition of any notes you may wish to make...

Page 12: ...or Glen Dimplex UK Ltd Glen Dimplex Europe Limited Millbrook House Grange Drive Hedge End Southampton SO30 2DF Airport Road Cloghran Co Dublin K67 VE08 Telephone 44 0 344 879 3588 Telephone 353 0 1 85...

Reviews: