Wire the electrical connections. 

11.

 

Make sure the mains supply is isolated. Switch off the mains electrical supply and remove fuses. 

12.

 

Feed the cable to the terminal block. Wire the fan as shown in Figure  F using the diagram appropriate to the fan 
model. 

13.

 

Connect the cable from the isolating switch to the electrical supply wiring. 

 
Fan Settings. 

 

SPEED SETTING 

The fans are factory set to low speed, but have two speed settings for different applications. Select either high or low speed 
by connecting the jumper between the centre and high or low speed pin on the jumper (see Figure E) 
 

DX100BTR / DX100BTS Only. 

 

To adjust the over-run period turn the control (T) clockwise to increase and anti-clockwise to decrease – see Figure D.

 

 
DX100BHTR / DX100BHTS – see figures D and E. 

 

The  pre-set  humidity  operation  is  factory  set  at  approximately  75%  Relative  Humidity  (RH),  but  can  be  adjusted 
between 65% and 85% RH by control H. 

 

The over-run timer is factory set at 15 minutes but can be adjusted from 30 seconds to 30 minutes by control T. 

 

Turn the controls clockwise to increase RH or time and anti-clockwise to decrease. 

 

Using the fan. 

DX100BR / DX100BS Only 

 

Operate the fan using the on/off switch (not supplied). Repeat to switch off. 

 

DX100BTR / DX100BTS Only 

 

Operate the fan using an on/off switch (not supplied). Note – the fan may take up to 10 seconds to turn on once the 
switch has been operated. When the switch is turned off, the fan continues to operate for the set time delay. To adjust 
the over-run period, turn the control “T” clockwise to increase and anti-clockwise to decrease – see Figure D. 

 

DX100BHTR / DX100BHTS Only. 

 

Automatic mode

 - The fan automatically adjusts to slow changes in natural humidity levels without operating the fan.  

If the humidity levels increase at a rate slower than 5% RH in 5 minutes, up to the pre-set humidity level, the fan will 
not be triggered by humidity. This is to prevent nuisance triggering of the fan. If humidity levels increase quicker than 
5% RH in 5 minutes the fan will operate. When relative humidity drops the fan continues to operate for the adjustable 
time delay. 

 

External operation

 - Use the external on/off switch. When the fan is switched off, the fan continues to operate for 

the adjustable time delay then goes into automatic mode.  

 
DX100BPR / DX100BPS Only 

 

Operate the fan by pulling and releasing the cord. Repeat to switch off. 

 

All Fans 

Re-fit the front cover by hooking in the top first, and then swing the cover down to clip into place. 

 
 
 
 
 
 

 

 

 

Cleaning (recommended once a month). 

1.

 

Before cleaning, isolate the fan completely from the mains supply. 

2.

 

Remove the front cover by depressing the latch on the underside of the cover and pulling off 
the front cover from the bottom. 

3.

 

To clean the front cover, either wipe it with a damp, lint free cloth or wash it with warm soapy 
water. Thoroughly dry the front cover and refit. 

4.

 

Do not immerse the fan in water or other liquids to clean any other parts of the fan. 

5.

 

Do not use strong detergents, solvents or chemical cleaners 

6.

 

Allow fan to dry thoroughly before use. 

7.

 

Apart from cleaning, no other maintenance is required. 

 

Disposal 

This product should not be disposed of with household waste. 
Please recycle where facilities exist. 
Check with your local authority for recycling advice. 

Summary of Contents for Simply Silent DX100BR

Page 1: ...in the fixed wiring Do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning Please leave this leaflet with the fan for t...

Page 2: ...in timer automatically operates the fan for a pre set delay time from 30 seconds to 30 minutes once humidity drops below the pre set Relative Humidity RH value External operation When switched off us...

Page 3: ...ack plate fixing positions Front Cover Removal Depress Cover Latch with tool remove Cover A C D Minimum 30 seconds Maximum 30 minutes Factory settings Timer 15 minutes RH 75 Wall tube quickfix clamps...

Page 4: ...Wiring and setting up E...

Page 5: ...f the hole As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room e g opposite the internal doorway Near the source of steam or odours Not wh...

Page 6: ...ighten the screws until the fan is firmly secured to the tube see figure B Alternately the fan back plate can be fixed directly to the wall using the screws and wall plugs supplied as described below...

Page 7: ...increase and anti clockwise to decrease see Figure D DX100BHTR DX100BHTS Only Automatic mode The fan automatically adjusts to slow changes in natural humidity levels without operating the fan If the h...

Page 8: ...rnational below United Kingdom Xpelair have a comprehensive range of services including Free technical advice help desk from Engineers on all aspects of ventilation Free design service quotations and...

Reviews: