Xpelair 93011AW Installation And Maintenance Instructions Manual Download Page 6

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Where to locate the fan. 

 

Locate it as high as possible. 

 

At least 110mm from the edges of the mounting surface to the centre of the hole. 

 

As far away as possible from and opposite to the main source of air replacement to ensure airflow across 

the room (e.g. opposite the internal doorway). 

 

Near the source of steam or odours. 

 

 

 

Not where ambient temperatures are likely to exceed 50°C. 

 

If installed in a kitchen fans must not be mounted immediately above a cooker hob, or eye level grill. 

 

If installing in a room containing a fuel burning device which has a non-balanced flue, it is the 

installer's responsibility to ensure that there is enough replacement air to prevent fumes being 

drawn down the flue when the fan is operating up to maximum extract. Refer to Building Regulations 

for specific requirements. 

 

Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied 

with energy other than electric. Requirements of all authorities concerned must be observed for 

exhaust air discharge and intake flow rates. 

 

Not suitable for use in possible chemical corrosive atmospheres. 

 

LV100PIRR / LV100PIRS Only – Siting must ensure detection of movement. Care should be taken to 

avoid obstruction that may affect detection beams – See Figure B. 

 

Transformer. 

 

In a loft or any convenient position on a wall (not suitable for ceiling mounting). 

The transformer must 

not be covered by loft insulation.

 

 

When wall mounting, the transformer must be oriented as shown in diagram  G  to fulfil ingress 

protection requirements

 

 

Not within 0.6m of a bath or shower cubicle, up to a height of 2.25m 

 

Not where ambient temperatures are likely to exceed 40°C

 

 

Wiring and setting up 

I2 

 

Summary of Contents for 93011AW

Page 1: ...et before commencing installation Do install each fan with a means for disconnection in all poles in the fixed wiring Do make sure the mains supply is switched off before attempting to make electrical...

Page 2: ...gral pull cord switch In automatic mode the built in timer automatically operates the fan for a pre set delay time from 30 seconds to 30 minutes once humidity drops below the pre set Relative Humidity...

Page 3: ...Back plate fixing positions Front Cover Removal Depress Cover Latch with tool remove Cover A C B...

Page 4: ...Minimum 30 seconds Maximum 30 minutes Factory settings Timer 15 minutes RH 75 D E H F G...

Page 5: ...Wiring and setting up I1...

Page 6: ...ract Refer to Building Regulations for specific requirements Exhaust air must not be discharged into a flue used for exhausting of fumes from appliances supplied with energy other than electric Requir...

Page 7: ...ated 2 core cable supply to transformer LV100R LV100S LV100PR LV100PS LV100HTR LV100HTS LV100HPTR LV100HPTS LV100PIRR LV100PIRS Suitably rated 3 core cable supply to transformer LV100TR LV100TS 1 Chec...

Page 8: ...e back plate to the wall ceiling using appropriate fasteners supplied See figure A 12 If using screws do not over tighten Mount the back draft shutter 13 Peel the backing from the foam strip supplied...

Page 9: ...ion LV100TR LV100TS LV100PIRR LV100PIRS only To adjust the over run period turn the control T clockwise to increase and anti clockwise to decrease see Figure H LV100HTR LV100HTS LV100HPTR LV100HPTS on...

Page 10: ...Automatic mode The fan automatically adjusts to slow changes in natural humidity levels without operating the fan If the humidity levels increase at a rate slower than 5 RH in 5 minutes up to the pre...

Page 11: ...This page has been left blank for the addition of any notes you may wish to make...

Page 12: ...or Glen Dimplex UK Ltd Glen Dimplex Europe Limited Millbrook House Grange Drive Hedge End Southampton SO30 2DF Airport Road Cloghran Co Dublin K67 VE08 Telephone 44 0 344 879 3588 Telephone 353 0 1 85...

Reviews: