Xpelair Premier DX200 Installation And Maintenance Instructions Manual Download Page 6

Operate the fan using an on/off switch 
(not supplied).

Built-in timer automatically operates fan 
for an adjustable over-run period of up to
20 minutes.

A double pole isolating switch with a 
minimum contact gap of 3mm (wall or 
ceiling mounted).

If metal switch boxes are used, earthing
regulations must be followed.

Suitably rated 3-core cable (DX200).

Suitably rated 4-core cable (DX200T).

3mm electrician's screwdriver and no. 1 
and 2 Pozidriv screwdrivers.

A wall or ceiling on/off switch (DX200T).

To prevent a possible hazardous        
situation from water ingress, a         
condensation trap (Xpelair no. XCT100) 
must be fitted as close as possible to 
the fan in all situations where any    
section of the ductwork is positioned 
higher than the fan itself.

Masonry drill, hammer & chisel (or 
117mm core drill equipment if available).

Mortar to make good the hole if required.

Wall tube for cavity walls. WD100      
available from Xpelair for walls up to 
280mm (11") thick, or a length of 100mm
internal diameter ducting.

Suitable exterior wall grille. (KHWG or 
CFWG100 available from Xpelair).

Glass Mounting Kit (GMK, available from 
Xpelair). Please refer to separate     
instruction leaflet for glass mounting kit.

These appliances are intended for
connection to fixed wiring.

Check that the electrical rating shown on
the fan matches the mains supply.

WARNING: THESE APPLIANCES MUST BE
EARTHED.

All installations must be supervised by a
qualified electrician.

Installations and wiring must conform to
current IEE Regulations (UK), local or
appropriate regulations (other countries).
It is the installer's responsibility to ensure
that the appropriate Building Codes of
Practice are adhered to.

If you have any queries before installing
these products or after they have been
installed, call the Xpelair Technical Hotline
+44 (0)8709 000430. Our Engineers are
there to help you during normal office
hours (UK only) and may be faxed at all
other times +44 (0)8709 000530.

Customers outside the UK may contact
your local Xpelair distributor, details of
which are available from the UK office.

All fans have the following features:

Wall mounting.

Ceiling mounting using appropriate   
ancillaries (available from Xpelair).

Glass mounting using Glass Mounting Kit
(GMK available from Xpelair).

Surface and flush mounting options.

Intended for ducted installations.

Choice of extract spigots for 100mm 
internal diameter ducting (wall duct 
WD100 available from Xpelair) or flat 
ducting (flat ducting adaptor FDA      
available from Xpelair).

Two speed operation. This allows        
economical use of energy, and low 
sound levels. High speed operation at 
110m

3

/h allows conformance to UK 

Building Regulations for utility rooms.

Low speed operation at 85m

3

/h allows 

conformance to UK Building Regulations 
for toilet and bathrooms.

6

Xpelair Centrifugal Ducted Fans
Premier DX200 & DX200T
Installation and operating instructions

PLEASE LEAVE THIS LEAFLET WITH THE FAN, FOR THE BENEFIT OF THE USER.

GB

Installing the fan

DX200

DX200T

If wall mounting the fan, you
will also need

If glass mounting the fan

What the installer will need

Description

If ceiling mounting the fan

Where to locate the fan

You will need to use the appropriate 
ancillaries for termination.

These items are available from Xpelair.

1 WT10 - Termination ducting kit.

2 CFWG100 - Soffit board termination grille

(white or grey).

3 FD100/3 and FD100/6 - Flexible ducting.

4 XCMK - Ceiling Mounting Kit.

Appropriate ceiling fixings and screws.

Locate it as high as possible.

As far away as possible from and      
opposite to the main source of air 
replacement to ensure airflow across the 
room (e.g. opposite the Internal        
doorway).

Near the source of steam or odours.

Not where ambient temperatures are   
likely to exceed 50

o

C.

If installed in a kitchen fans must not be
mounted immediately above a cooker 
hob, or eye level grill.

If installing in a room containing a fuel 
burning device which has a non-        
balanced flue, it is the installer's 
responsibility to ensure that there is 
enough replacement air to prevent 
fumes being drawn down the flue when 
the fan is operating up to maximum 
extract.

Refer to Building Regulations for      
specific requirements.

Exhaust air must not be discharged into 
a flue used for exhausting of fumes 
from appliances supplied with energy 
other than electric. Requirements of all 
authorities concerned must be observed
for exhaust air discharge and intake 
flow rates.

When intended for use in possible 
chemical corrosive atmospheres,     
consult our Technical Service 
Department. (For overseas markets  
contact you local Xpelair distributor).

This electrical product, if installed in a 
shower room or bathroom must be     
situated so that it cannot be touched by 
persons making use of the bath or 
shower.

Summary of Contents for DX200

Page 1: ...GB F D NL N P I GR a Xpelair Centrifugual Ducted Fans DX200 Remote Switched DX200T Timer Installation and maintenance instructions Retain for future reference ...

Page 2: ...2 A B ...

Page 3: ... C D DX200 DX200T DOUBLE POLE ISOLATING SWITCH FUSE FAN TERMINALS CHANGE OVER SPEED SWITCH COS DOUBLE POLE ISOLATING SWITCH FUSE FAN TERMINALS CHANGE OVER SPEED SWITCH COS LAMP IF REQUIRED ON OFF SWITCH ...

Page 4: ...4 E F ...

Page 5: ...5 G ...

Page 6: ...flush mounting options Intended for ducted installations Choice of extract spigots for 100mm internal diameter ducting wall duct WD100 available from Xpelair or flat ducting flat ducting adaptor FDA available from Xpelair Two speed operation This allows economical use of energy and low sound levels High speed operation at 110m3 h allows conformance to UK Building Regulations for utility rooms Low ...

Page 7: ...LECTRICAL SUPPLY AT THIS STAGE Connection to the supply can be made by a flexible 3 core cable complete with 3 pin plug top for insertion into an approved 10A GPO or directly wired through an approved 10A wall mounted surface switch with at least 3mm clearance between contacts These models are permanently connected to the supply and operation is controlled by a remote switch They should be directl...

Page 8: ...ws 2 Pass the electrical cables into the fan box 5 through the front cable inlet hole 3 Offer the fan box 5 up to the wall making sure the ducting enters the outer wall Ensure that the ducting slopes down away from the fan to allow drainage of any incoming water to the outside 4 Tighten up the three screws until the fan is clamped to the inner wall The fan body clamps º will rotate to an automatic...

Page 9: ...tely from the mains electricity supply Allow 3 minutes for the impeller to stop rotating 1 Remove the baffle plate 1 by unclipping it using a sideways action 2 Clean the baffle plate 1 by immersing in warm soapy water Dry thoroughly 3 The front cover 2 and surround 9 should be wiped clean with a damp cloth 4 Refit the baffle plate 1 onto the front cover 2 by locating the clips and carefully snappi...

Page 10: ...nternational below UK Xpelair have a comprehensive range of services including Free technical advice help desk from Engineers on all aspects of ventilation Free design service quotations and site surveys Service and maintenance contracts to suit all requirements Please ask for details By telephone on Techline 44 0 8709 000430 By fax on Techfax 44 0 8709 000530 At the address below Head Office UK S...

Reviews: