Operate the fan using an on/off switch
(not supplied).
♦
Built-in timer automatically operates fan
for an adjustable over-run period of up to
20 minutes.
♦
A double pole isolating switch with a
minimum contact gap of 3mm (wall or
ceiling mounted).
♦
If metal switch boxes are used, earthing
regulations must be followed.
♦
Suitably rated 3-core cable (DX200).
♦
Suitably rated 4-core cable (DX200T).
♦
3mm electrician's screwdriver and no. 1
and 2 Pozidriv screwdrivers.
♦
A wall or ceiling on/off switch (DX200T).
♦
To prevent a possible hazardous
situation from water ingress, a
condensation trap (Xpelair no. XCT100)
must be fitted as close as possible to
the fan in all situations where any
section of the ductwork is positioned
higher than the fan itself.
♦
Masonry drill, hammer & chisel (or
117mm core drill equipment if available).
♦
Mortar to make good the hole if required.
♦
Wall tube for cavity walls. WD100
available from Xpelair for walls up to
280mm (11") thick, or a length of 100mm
internal diameter ducting.
♦
Suitable exterior wall grille. (KHWG or
CFWG100 available from Xpelair).
♦
Glass Mounting Kit (GMK, available from
Xpelair). Please refer to separate
instruction leaflet for glass mounting kit.
These appliances are intended for
connection to fixed wiring.
Check that the electrical rating shown on
the fan matches the mains supply.
WARNING: THESE APPLIANCES MUST BE
EARTHED.
All installations must be supervised by a
qualified electrician.
Installations and wiring must conform to
current IEE Regulations (UK), local or
appropriate regulations (other countries).
It is the installer's responsibility to ensure
that the appropriate Building Codes of
Practice are adhered to.
If you have any queries before installing
these products or after they have been
installed, call the Xpelair Technical Hotline
+44 (0)8709 000430. Our Engineers are
there to help you during normal office
hours (UK only) and may be faxed at all
other times +44 (0)8709 000530.
Customers outside the UK may contact
your local Xpelair distributor, details of
which are available from the UK office.
♦
All fans have the following features:
♦
Wall mounting.
♦
Ceiling mounting using appropriate
ancillaries (available from Xpelair).
♦
Glass mounting using Glass Mounting Kit
(GMK available from Xpelair).
♦
Surface and flush mounting options.
♦
Intended for ducted installations.
♦
Choice of extract spigots for 100mm
internal diameter ducting (wall duct
WD100 available from Xpelair) or flat
ducting (flat ducting adaptor FDA
available from Xpelair).
♦
Two speed operation. This allows
economical use of energy, and low
sound levels. High speed operation at
110m
3
/h allows conformance to UK
Building Regulations for utility rooms.
Low speed operation at 85m
3
/h allows
conformance to UK Building Regulations
for toilet and bathrooms.
6
Xpelair Centrifugal Ducted Fans
Premier DX200 & DX200T
Installation and operating instructions
PLEASE LEAVE THIS LEAFLET WITH THE FAN, FOR THE BENEFIT OF THE USER.
GB
Installing the fan
DX200
DX200T
If wall mounting the fan, you
will also need
If glass mounting the fan
What the installer will need
Description
If ceiling mounting the fan
Where to locate the fan
♦
You will need to use the appropriate
ancillaries for termination.
♦
These items are available from Xpelair.
1 WT10 - Termination ducting kit.
2 CFWG100 - Soffit board termination grille
(white or grey).
3 FD100/3 and FD100/6 - Flexible ducting.
4 XCMK - Ceiling Mounting Kit.
♦
Appropriate ceiling fixings and screws.
♦
Locate it as high as possible.
♦
As far away as possible from and
opposite to the main source of air
replacement to ensure airflow across the
room (e.g. opposite the Internal
doorway).
♦
Near the source of steam or odours.
♦
Not where ambient temperatures are
likely to exceed 50
o
C.
♦
If installed in a kitchen fans must not be
mounted immediately above a cooker
hob, or eye level grill.
♦
If installing in a room containing a fuel
burning device which has a non-
balanced flue, it is the installer's
responsibility to ensure that there is
enough replacement air to prevent
fumes being drawn down the flue when
the fan is operating up to maximum
extract.
Refer to Building Regulations for
specific requirements.
Exhaust air must not be discharged into
a flue used for exhausting of fumes
from appliances supplied with energy
other than electric. Requirements of all
authorities concerned must be observed
for exhaust air discharge and intake
flow rates.
♦
When intended for use in possible
chemical corrosive atmospheres,
consult our Technical Service
Department. (For overseas markets
contact you local Xpelair distributor).
♦
This electrical product, if installed in a
shower room or bathroom must be
situated so that it cannot be touched by
persons making use of the bath or
shower.